Give this junction temperature calculator a semiconductor’s power and a datasheet thermal metric and it returns Tj, the most power the part can dissipate at your ambient, or the hottest ambient it can tolerate. The derating curve shows how the allowed power falls with temperature.

Solve for
Examples
Datasheet metric

θJA: to still air. θJC: to a heatsunk case. ψJT and ψJB: from a measured package or board temperature.

°C/W
W
°C
°C

The data sheet’s maximum operating junction temperature: often 125, 150 or 175 °C. Subtract your own design margin.

Junction temperature Tj

75 °C

Rise above ambient
50 °C
Margin to Tj max
75 °C
Maximum power at this ambient temperature
2.5 W
Derating factor
20 mW/°C

⚠ θJA is measured on a JEDEC test board (JESD51) in still air, and most of the heat leaves through that board. TI’s SPRA953 calls it a comparison figure, not a property of the package, so a real board can land well away from this estimate.

Derating curve: maximum power against temperature
01234050100150Ambient temperature (°C)Maximum power (W)1 W load25 °C

Maximum power by ambient temperature (Tj max 150 °C, θJA = 50 °C/W)

Ambient temperatureMaximum power
25 °C2.5 W
40 °C2.2 W
50 °C2 W
60 °C1.8 W
70 °C1.6 W
85 °C1.3 W
105 °C900 mW
125 °C500 mW

How do you calculate junction temperature?

Use Tj = Ta + P × θJA, where θJA is the junction-to-ambient thermal resistance from the datasheet. A TPS563200 buck converter (θJA = 87.9 °C/W) dissipating 0.5 W at 60 °C ambient reaches 104 °C. Treat that as an estimate, because θJA is measured on a JEDEC test board and yours will differ. To check real hardware, measure the top of the package and use ψJT instead.

Junction temperature formula

Each thermal metric has the same form: a reference temperature, plus the power times the metric for that reference point.

Tj = Tref + P × θ
Tj
junction temperature in °C
Tref
temperature of the reference point in °C (air, case, top of package or board)
P
power dissipated in the part in W
θ
thermal metric for that reference in °C/W

Rearranged for the limit, with Tj,max from Absolute Maximum Ratings:

Pmax = (Tj,max − Tref) ÷ θ     Tref,max = Tj,max − P × θ

The derating factor, the slope of the derating curve, is 1 ÷ θ in W/°C.

Which thermal metric to use

The metrics are not interchangeable. Each one is measured to a particular reference point: junction-to-case thermal resistance, for one, assumes a case surface held at a uniform temperature.

MetricReference pointUse it forDefined in
θJAStill airComparing packages, and first estimatesJESD51 test boards
θJCCase surface held at a uniform temperatureParts on a heatsink or cold plateJESD51-1 definition
ψJTThermocouple on top of the packageFinding Tj on real hardware with no heatsinkJESD51-2
ψJBPCB at the center pinFinding Tj from a measured board temperatureJESD51-6

How to calculate junction temperature: worked examples

Example 1: a buck converter in SOT-23-6

The TPS563200 data sheet lists θJA = 87.9 °C/W. At 0.5 W and 60 °C ambient, Tj = 60 + 0.5 × 87.9 = 104 °C. With a 150 °C limit, the same load could tolerate an ambient up to 106 °C on the JEDEC board.

Example 2: a TO-220 MOSFET with no heatsink

The IRFZ44N has θJA = 62 °C/W (max) and Tj,max = 175 °C. At 40 °C ambient, P = (175 − 40) ÷ 62 = 2.18 W. Beyond that it needs a heatsink, which the heatsink calculator sizes.

Example 3: checking a prototype with a thermocouple

A thermocouple on top of the same TPS563200 reads 85 °C at 0.5 W. With ψJT = 1.9 °C/W, Tj = 85 + 0.5 × 1.9 = 85.95 °C. The correction is under 1 °C, which is why the top-of-package reading is such a good proxy on plastic packages without a heatsink.

Maximum power by θJA and ambient temperature

Pmax for a junction limit of 150 °C. For 125 °C parts, the figures fall by 25 ÷ θJA watts.

θJA \ Ambient25 °C50 °C70 °C85 °C
20 °C/W6.25 W5 W4 W3.25 W
40 °C/W3.13 W2.5 W2 W1.63 W
60 °C/W2.08 W1.67 W1.33 W1.08 W
90 °C/W1.39 W1.11 W889 mW722 mW
120 °C/W1.04 W833 mW667 mW542 mW
200 °C/W625 mW500 mW400 mW325 mW

What datasheets actually quote

Values copied from the data sheets listed under Sources. The two power MOSFET values are maximums. The TI values come from each data sheet’s thermal information table. The LM7805 Tj max is its 125 °C operating limit; its absolute maximum is 150 °C.

PartPackageθJAθJCψJTTj maxPmax at 50 °C
TPS563200SOT-23-687.9 °C/W42.2 (top) °C/W1.9 °C/W150 °C1.14 W
LM7805TO-22023.9 °C/W16.7 (top), 1.7 (tab) °C/W3.2 °C/W125 °C3.14 W
IRFZ44NTO-22062 °C/W1.5 °C/Wnot given175 °C2.02 W
IRFP250NTO-24740 °C/W0.7 °C/Wnot given175 °C3.13 W

Where junction temperature estimates go wrong

The biggest error is using θJA as if it were a property of the part. The LM7805 data sheet shows the problem: its thermal table lists 23.9 °C/W for the TO-220 package while a note under its ratings gives 54 °C/W. At 50 °C and a 125 °C limit, that is 3.14 W or 1.39 W. When the answer matters, measure.

A θJC figure also needs care, because data sheets now separate the top of the package from the bottom. On a TO-220 the heatsink touches the metal tab, which is the bottom value, and the top value is about ten times larger for the LM7805. The same model does not cover short pulses: these are steady-state numbers, and transient heating needs the part’s thermal impedance curve.

Glossary

Junction temperature (Tj)
The temperature of the active silicon. It sets reliability and whether the part is within its ratings.
θJA
Junction-to-ambient thermal resistance in °C/W, measured on a JEDEC test board in still air.
θJC
Junction-to-case thermal resistance in °C/W, to a stated case surface held at a uniform temperature.
ψJT
Junction-to-top characterization parameter. It converts a measured top-of-package temperature to Tj, but is not a true thermal resistance.
ψJB
Junction-to-board characterization parameter, used with a measured PCB temperature at the package’s center pin.
Derating factor
The reduction in allowed power per degree of temperature rise, in W/°C, equal to 1/θ.

Related guides

Frequently asked questions

What is the junction temperature formula?

Tj = Ta + P × θJA for the ambient case, or more generally the reference temperature plus power times the thermal metric for that reference. A part with θJA = 87.9 °C/W dissipating 0.5 W at 60 °C runs at 104 °C.

What is the difference between θJA and θJC?

θJA is measured from the junction to still air on a defined JEDEC test board. θJC is from the junction to one case surface held at a fixed temperature, and it is meant for parts on a heatsink. Using θJC with the air temperature gives a junction temperature that is far too low.

Why does my board not match the datasheet θJA?

θJA describes the package on a JEDEC test board, and in those tests about 70 to 95 % of the heat leaves through the board. A different layout, copper area, airflow or altitude changes it, so TI recommends using θJA to compare packages and not to predict a junction temperature.

What is ψJT, and how do I use it?

ψJT relates the temperature on top of the package to the junction temperature, Tj = Ttop + P × ψJT. Glue a fine thermocouple (36 gauge or smaller) to the top center of the package and add the small correction: at 0.5 W with ψJT = 1.9 °C/W the junction is only 0.95 °C above the case top. Do not use it with a heatsink fitted.

How do I derate power with temperature?

Allowed power falls in a straight line from the rated point to zero at Tj max, with a slope of 1/θ. The IRFP250N, with θJC = 0.7 °C/W, has a calculated factor of 1.4 W/°C and 214 W at a 25 °C case, in line with the 1.4 W/°C and 214 W in its data sheet.

What maximum junction temperature should I use?

Use the maximum operating junction temperature from the data sheet: 125 °C, 150 °C and 175 °C are common. It can sit below the absolute maximum (the LM7805 is specified to 125 °C with a 150 °C absolute maximum), so use the lower figure. It is a limit, not a design target, because the electrical specifications do not apply above it, so subtract the margin your reliability targets need.

How does a MOSFET junction temperature calculation work?

It uses the same formula with the MOSFET’s total loss as P. A bare IRFZ44N (θJA = 62 °C/W) at 40 °C ambient reaches its 175 °C limit at 2.18 W. On a heatsink, start from the case temperature and θJC instead.

What is the junction-to-ambient thermal resistance formula?

The theta JA formula is θJA = (Tj − Ta) ÷ P, the rise from ambient to junction per watt, measured on a JEDEC test board in still air. It is the same relation as Tj = Ta + P × θJA, and θJC uses the case temperature in place of Ta.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.