How do you calculate LDO power dissipation and junction temperature?
Use PD = (Vin − Vout) × Iout + Vin × Iq, then TJ = TA + PD × RθJA. An AMS1117-3.3 running from 5 V at 500 mA with its typical 5 mA of quiescent current burns 875 mW; in a SOT-223 at 90 °C/W and 25 °C ambient, the junction reaches 103.8 °C, against a 125 °C limit.
LDO power dissipation formula and junction temperature
Linear regulator power dissipation follows from an energy balance: all the power the regulator takes from the input and does not deliver to the load becomes heat in the die. The heat flows through the package and the board to the air, and the junction temperature rises in proportion.
PD = (Vin − Vout) × Iout + Vin × Iq
- PD
- power dissipated in the regulator, in W
- Vin, Vout
- input and output voltage, in V
- Iout
- output (load) current, in A
- Iq
- quiescent or ground current, in A
TJ = TA + PD × RθJA
- TJ
- junction temperature in °C
- TA
- ambient temperature in °C
- RθJA
- junction-to-ambient thermal resistance in °C/W
Rearranged for the limits:
PD(max) = (TJ(max) − TA) ÷ RθJA
Iout(max) = (PD(max) − Vin × Iq) ÷ (Vin − Vout)
RθJA(max) = (TJ(max) − TA) ÷ PD
LDO thermal calculation examples
Example 1: AMS1117-3.3 from 5 V at 500 mA
PD = (5 − 3.3) × 0.5 + 5 × 0.005 = 875 mW. With the 90 °C/W the AMS1117 data sheet gives for a SOT-223, the rise is 78.8 °C, so TJ = 103.8 °C at 25 °C ambient. The same board can only tolerate an ambient of 46.2 °C.
Example 2: 12 V to 3.3 V at 200 mA in a warm enclosure
PD = (12 − 3.3) × 0.2 + 12 × 0.005 = 1.8 W. An LM1117 SOT-223 on a JEDEC board (61.6 °C/W) at 40 °C reaches 150.9 °C, well over the limit, and the most it can supply here is 152 mA. Lower the input, or use a switching regulator.
Example 3: choosing a package with a derated limit (TI SLVA118A, example 2)
A 5 V +5 % input, a 3.3 V −2 % output and 0.95 A give a worst case of PD = (5.25 − 3.234) × 0.95 = 1.92 W, ignoring Iq. With TJ derated to 115 °C at 50 °C ambient, RθJA must be at most 33.9 °C/W, which rules out most small packages.
Maximum LDO power dissipation by package
PD(max) = (125 °C − TA) ÷ RθJA. Each RθJA comes from a TI or AMS document: the LM1117, TLV755P and LP5907 JEDEC figures, the LM1117 copper-area table, the AMS1117’s own table, and for the TO-220 with no heat sink the top of the range in TI SLVA118A. They are not interchangeable with a different part in the same package, and a real PCB is often worse.
| Package | RθJA | 25 °C | 50 °C | 70 °C | 85 °C | Source |
|---|
| SOT-23-5 | 231.1 °C/W | 433 mW | 325 mW | 238 mW | 173 mW | TLV755P DBV package, JEDEC board (TI SBVS320D §5.4) |
| SOT-23-5 (LP5907) | 193.4 °C/W | 517 mW | 388 mW | 284 mW | 207 mW | LP5907 DBV package (TI SNVS798Q §5.4) |
| SO-8 | 160 °C/W | 625 mW | 469 mW | 344 mW | 250 mW | AMS1117 data sheet, Absolute Maximum Ratings |
| SOT-223, minimum pad | 136 °C/W | 735 mW | 551 mW | 404 mW | 294 mW | LM1117, 0.0123 in² of top copper (TI SNOS412Q Table 9-2) |
| SOT-223 (AMS1117) | 90 °C/W | 1.11 W | 833 mW | 611 mW | 444 mW | AMS1117 data sheet; 46 °C/W to over 90 °C/W depending on copper |
| SOT-223, 1 in² copper | 66 °C/W | 1.52 W | 1.14 W | 833 mW | 606 mW | LM1117, 1 in² of top copper (TI SNOS412Q Table 9-2) |
| SOT-223, JEDEC | 61.6 °C/W | 1.62 W | 1.22 W | 893 mW | 649 mW | LM1117 DCY package, JEDEC board (TI SNOS412Q §7.4) |
| TO-252, minimum pad | 103 °C/W | 971 mW | 728 mW | 534 mW | 388 mW | LM1117, 0.0123 in² of top copper (TI SNOS412Q Table 9-2) |
| TO-252 (AMS1117) | 80 °C/W | 1.25 W | 938 mW | 688 mW | 500 mW | AMS1117 data sheet, Absolute Maximum Ratings |
| TO-252, 1 in² copper | 47 °C/W | 2.13 W | 1.6 W | 1.17 W | 851 mW | LM1117, 1 in² of top copper (TI SNOS412Q Table 9-2) |
| TO-252, JEDEC | 45.1 °C/W | 2.22 W | 1.66 W | 1.22 W | 887 mW | LM1117 NDP package, JEDEC board (TI SNOS412Q §7.4) |
| TO-263 | 41.3 °C/W | 2.42 W | 1.82 W | 1.33 W | 969 mW | LM1117 KTT package, JEDEC board (TI SNOS412Q §7.4) |
| WSON-8 | 39.3 °C/W | 2.54 W | 1.91 W | 1.4 W | 1.02 W | LM1117 NGN package, JEDEC board (TI SNOS412Q §7.4) |
| TO-220, no heat sink | 58 °C/W | 1.72 W | 1.29 W | 948 mW | 690 mW | Top of the 22 to 58 °C/W TI gives for a TO-220 with no airflow (TI SLVA118A Figure 5) |
| TO-220, JEDEC | 23.8 °C/W | 4.2 W | 3.15 W | 2.31 W | 1.68 W | LM1117 NDE package, JEDEC board (TI SNOS412Q §7.4) |
How copper area changes RθJA
Measured data from TI’s LM1117 data sheet (Table 9-2), with the tab on top-side copper: 1 oz for SOT-223 and 2 oz for TO-252. The last two columns are the dissipation that holds 125 °C at 50 °C ambient.
| Top copper | SOT-223 RθJA | TO-252 RθJA | SOT-223 PD(max) | TO-252 PD(max) |
|---|
| 0.0123 in² | 136 °C/W | 103 °C/W | 551 mW | 728 mW |
| 0.066 in² | 123 °C/W | 87 °C/W | 610 mW | 862 mW |
| 0.3 in² | 84 °C/W | 60 °C/W | 893 mW | 1.25 W |
| 0.53 in² | 75 °C/W | 54 °C/W | 1 W | 1.39 W |
| 0.76 in² | 69 °C/W | 52 °C/W | 1.09 W | 1.44 W |
| 1 in² | 66 °C/W | 47 °C/W | 1.14 W | 1.6 W |
Keeping an LDO cool
The numbers that move the result most are the input voltage and the copper. Dropping 12 V to 3.3 V instead of 5 V to 3.3 V produces about five times the heat. Put a pre-regulator ahead of the LDO, or share the drop with a series resistor when the input is high. On the board, solder the tab to as much copper as you can, and connect it through vias to an inner or back plane. A TO-220 shows how much this matters: at 25 °C it can shed 4.2 W at the 23.8 °C/W of TI’s JEDEC board, but only 1.72 W at 58 °C/W with no heat sink or board copper.
Check dropout separately from heat: the output sags once Vin − Vout falls below the data sheet’s dropout, which rises with load and temperature. An AMS1117 is 1.1 V typical at 0.8 A. A TLV755P in SOT-23-5 with an output from 3.3 V to below 5 V is 150 mV typical at 500 mA, with limits of 215 mV up to 85 °C and 238 mV up to 125 °C. This LDO calculator is steady state and assumes a uniform ambient: a nearby hot component, an enclosure or a short load pulse all change the answer, and short pulses can exceed the average power without damage.
Glossary
- LDO
- Low-dropout regulator: a linear regulator that holds its output with a small input-to-output difference.
- Quiescent current (Iq)
- The current the regulator draws for itself, returned to ground rather than delivered to the load.
- Dropout voltage
- The smallest input-to-output difference at which the output is still in regulation.
- Junction temperature (TJ)
- The temperature of the silicon, which is what the ratings apply to.
- RθJA
- Junction-to-ambient thermal resistance in °C/W. It depends on the board as well as the package.
- Thermal shutdown
- An internal protection that turns the output off when the junction gets too hot.
Frequently asked questions
How do you calculate LDO power dissipation?
The LDO power loss calculation uses PD = (Vin − Vout) × Iout + Vin × Iq. The first term is the voltage the regulator drops times the load current, and the second is the input voltage times the quiescent (ground) current. Use the highest input the regulator will actually see.
How much power does a 5 V to 3.3 V LDO dissipate at 1 A?
1.73 W with a 5 mA quiescent current: 1.7 V × 1 A plus 5 V × 5 mA. An LDO at this load burns about a third of its input power as heat.
How much current can a SOT-223 LDO deliver?
It depends on the voltage drop and the copper. From 5 V to 3.3 V at 25 °C ambient, a SOT-223 on a JEDEC board (61.6 °C/W) reaches the 125 °C limit at 940 mA. On a minimum pad (136 °C/W) it reaches it at only 418 mA.
Does the quiescent current matter?
A bipolar 1117-style regulator draws about 5 mA, which is a few percent of the heat at full load but can be most of it at light load. A modern CMOS LDO with tens of microamps is negligible at any load. It matters most at high input voltage and light load, where Vin × Iq can exceed the load term.
What is the maximum junction temperature of an LDO?
Most LDOs are rated for continuous operation up to 125 °C. Thermal shutdown is usually higher (165 °C on the TLV755P), and it protects the part but is not an operating point. Many designs derate further, as in TI SLVA118A which uses 115 °C.
Can I trust the RθJA in the data sheet?
As a comparison between packages, yes; as a prediction for your board, only roughly. TI SPRA953 says RθJA is a property of the package, PCB and environment together. The AMS1117 data sheet gives a SOT-223 range from 46 °C/W to over 90 °C/W depending on copper.
When should I use a switching regulator instead of an LDO?
When the drop is large or the current is high. An LDO’s efficiency is about Vout ÷ Vin, so 12 V to 3.3 V at 200 mA is 27 % efficient and burns 1.8 W. A buck converter wastes far less of that, at the cost of switching noise and more parts.
How do you calculate LDO efficiency?
Efficiency is Vout × Iout ÷ (Vin × (Iout + Iq)), which is about Vout ÷ Vin once the load is well above Iq. From 5 V to 3.3 V at 500 mA with 5 mA of Iq it is 65 %, and this LDO efficiency calculator lists the figure next to the junction temperature.
More free PCB tools
See all free electronics tools →
- Regulator feedback resistor calculatorFeedback divider for an adjustable regulator: the resistor pair for your output voltage from the reference voltage.
- LM317 calculatorOutput voltage of an LM317 from R1 and R2, or the standard resistor pair for a voltage, with dropout and heat.
- Heatsink calculatorMaximum heatsink thermal resistance for a part to stay below its junction limit, from power, θJC and the interface.
- LM317 constant current calculatorSet resistor for an LM317 constant-current source or LED driver, its power, and the supply headroom you need.
- Junction temperature calculatorJunction temperature from power and θJA or θJC, the maximum power for your ambient, and a derating curve.
- MOSFET power loss calculatorConduction, switching and gate-drive losses of a MOSFET in a switching circuit, and the junction temperature they cause.
Design the whole board, not one number
ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.