NewAI Part GeneratorFree to get started
FREE TOOL

LDO power dissipation calculator

Find the power a linear regulator burns, how hot its junction gets in a given package, and the most current it can deliver before reaching its limit. This LDO power dissipation calculator compares packages from SOT-23 to TO-220 using data sheet thermal figures.

Solve for
Examples
V

Use the highest input the regulator will see.

V
A
A

From the data sheet, at your load if it is load dependent.

°C
°C

Most LDOs are rated to 125 °C.

V

At this load, from the data sheet, to check regulation.

A

Junction temperature

103.8 °C

limit 125 °C

Power dissipated
875 mW
Temperature rise
78.8 °C
Maximum power in this package
1.11 W
Maximum output current
639 mA thermal limit
Maximum ambient at this load
46.25 °C
Input-output voltage
1.7 V
Efficiency
65.3 %

90 °C/W: AMS1117 data sheet; 46 °C/W to over 90 °C/W depending on copper. RθJA depends on the board, so measure or simulate before you rely on it.

Junction temperature against output current
204060801001201401601800200m400m600m800mOutput current (A)Junction temperature (°C)125 °C limitLoad 500 mALimit 639 mA

Junction temperature by package at 875 mW

PackageRθJAJunctionResult
SOT-23-5231.1 °C/W227.2 °CToo hot
SOT-23-5 (LP5907)193.4 °C/W194.2 °CToo hot
SO-8160 °C/W165.0 °CToo hot
SOT-223, minimum pad136 °C/W144.0 °CToo hot
SOT-223 (AMS1117)90 °C/W103.8 °COK
SOT-223, 1 in² copper66 °C/W82.8 °COK
SOT-223, JEDEC61.6 °C/W78.9 °COK
TO-252, minimum pad103 °C/W115.1 °COK
TO-252 (AMS1117)80 °C/W95.0 °COK
TO-252, 1 in² copper47 °C/W66.1 °COK
TO-252, JEDEC45.1 °C/W64.5 °COK
TO-26341.3 °C/W61.1 °COK
WSON-839.3 °C/W59.4 °COK
TO-220, no heat sink58 °C/W75.8 °COK
TO-220, JEDEC23.8 °C/W45.8 °COK

How do you calculate LDO power dissipation and junction temperature?

Use PD = (Vin − Vout) × Iout + Vin × Iq, then TJ = TA + PD × RθJA. An AMS1117-3.3 running from 5 V at 500 mA with its typical 5 mA of quiescent current burns 875 mW; in a SOT-223 at 90 °C/W and 25 °C ambient, the junction reaches 103.8 °C, against a 125 °C limit.

LDO power dissipation formula and junction temperature

Linear regulator power dissipation follows from an energy balance: all the power the regulator takes from the input and does not deliver to the load becomes heat in the die. The heat flows through the package and the board to the air, and the junction temperature rises in proportion.

PD = (Vin − Vout) × Iout + Vin × Iq
PD
power dissipated in the regulator, in W
Vin, Vout
input and output voltage, in V
Iout
output (load) current, in A
Iq
quiescent or ground current, in A
TJ = TA + PD × RθJA
TJ
junction temperature in °C
TA
ambient temperature in °C
RθJA
junction-to-ambient thermal resistance in °C/W

Rearranged for the limits:

PD(max) = (TJ(max) − TA) ÷ RθJA
Iout(max) = (PD(max) − Vin × Iq) ÷ (Vin − Vout)
RθJA(max) = (TJ(max) − TA) ÷ PD

LDO thermal calculation examples

Example 1: AMS1117-3.3 from 5 V at 500 mA

PD = (5 − 3.3) × 0.5 + 5 × 0.005 = 875 mW. With the 90 °C/W the AMS1117 data sheet gives for a SOT-223, the rise is 78.8 °C, so TJ = 103.8 °C at 25 °C ambient. The same board can only tolerate an ambient of 46.2 °C.

Example 2: 12 V to 3.3 V at 200 mA in a warm enclosure

PD = (12 − 3.3) × 0.2 + 12 × 0.005 = 1.8 W. An LM1117 SOT-223 on a JEDEC board (61.6 °C/W) at 40 °C reaches 150.9 °C, well over the limit, and the most it can supply here is 152 mA. Lower the input, or use a switching regulator.

Example 3: choosing a package with a derated limit (TI SLVA118A, example 2)

A 5 V +5 % input, a 3.3 V −2 % output and 0.95 A give a worst case of PD = (5.25 − 3.234) × 0.95 = 1.92 W, ignoring Iq. With TJ derated to 115 °C at 50 °C ambient, RθJA must be at most 33.9 °C/W, which rules out most small packages.

Maximum LDO power dissipation by package

PD(max) = (125 °C − TA) ÷ RθJA. Each RθJA comes from a TI or AMS document: the LM1117, TLV755P and LP5907 JEDEC figures, the LM1117 copper-area table, the AMS1117’s own table, and for the TO-220 with no heat sink the top of the range in TI SLVA118A. They are not interchangeable with a different part in the same package, and a real PCB is often worse.

PackageRθJA25 °C50 °C70 °C85 °CSource
SOT-23-5231.1 °C/W433 mW325 mW238 mW173 mWTLV755P DBV package, JEDEC board (TI SBVS320D §5.4)
SOT-23-5 (LP5907)193.4 °C/W517 mW388 mW284 mW207 mWLP5907 DBV package (TI SNVS798Q §5.4)
SO-8160 °C/W625 mW469 mW344 mW250 mWAMS1117 data sheet, Absolute Maximum Ratings
SOT-223, minimum pad136 °C/W735 mW551 mW404 mW294 mWLM1117, 0.0123 in² of top copper (TI SNOS412Q Table 9-2)
SOT-223 (AMS1117)90 °C/W1.11 W833 mW611 mW444 mWAMS1117 data sheet; 46 °C/W to over 90 °C/W depending on copper
SOT-223, 1 in² copper66 °C/W1.52 W1.14 W833 mW606 mWLM1117, 1 in² of top copper (TI SNOS412Q Table 9-2)
SOT-223, JEDEC61.6 °C/W1.62 W1.22 W893 mW649 mWLM1117 DCY package, JEDEC board (TI SNOS412Q §7.4)
TO-252, minimum pad103 °C/W971 mW728 mW534 mW388 mWLM1117, 0.0123 in² of top copper (TI SNOS412Q Table 9-2)
TO-252 (AMS1117)80 °C/W1.25 W938 mW688 mW500 mWAMS1117 data sheet, Absolute Maximum Ratings
TO-252, 1 in² copper47 °C/W2.13 W1.6 W1.17 W851 mWLM1117, 1 in² of top copper (TI SNOS412Q Table 9-2)
TO-252, JEDEC45.1 °C/W2.22 W1.66 W1.22 W887 mWLM1117 NDP package, JEDEC board (TI SNOS412Q §7.4)
TO-26341.3 °C/W2.42 W1.82 W1.33 W969 mWLM1117 KTT package, JEDEC board (TI SNOS412Q §7.4)
WSON-839.3 °C/W2.54 W1.91 W1.4 W1.02 WLM1117 NGN package, JEDEC board (TI SNOS412Q §7.4)
TO-220, no heat sink58 °C/W1.72 W1.29 W948 mW690 mWTop of the 22 to 58 °C/W TI gives for a TO-220 with no airflow (TI SLVA118A Figure 5)
TO-220, JEDEC23.8 °C/W4.2 W3.15 W2.31 W1.68 WLM1117 NDE package, JEDEC board (TI SNOS412Q §7.4)

How copper area changes RθJA

Measured data from TI’s LM1117 data sheet (Table 9-2), with the tab on top-side copper: 1 oz for SOT-223 and 2 oz for TO-252. The last two columns are the dissipation that holds 125 °C at 50 °C ambient.

Top copperSOT-223 RθJATO-252 RθJASOT-223 PD(max)TO-252 PD(max)
0.0123 in²136 °C/W103 °C/W551 mW728 mW
0.066 in²123 °C/W87 °C/W610 mW862 mW
0.3 in²84 °C/W60 °C/W893 mW1.25 W
0.53 in²75 °C/W54 °C/W1 W1.39 W
0.76 in²69 °C/W52 °C/W1.09 W1.44 W
1 in²66 °C/W47 °C/W1.14 W1.6 W

Keeping an LDO cool

The numbers that move the result most are the input voltage and the copper. Dropping 12 V to 3.3 V instead of 5 V to 3.3 V produces about five times the heat. Put a pre-regulator ahead of the LDO, or share the drop with a series resistor when the input is high. On the board, solder the tab to as much copper as you can, and connect it through vias to an inner or back plane. A TO-220 shows how much this matters: at 25 °C it can shed 4.2 W at the 23.8 °C/W of TI’s JEDEC board, but only 1.72 W at 58 °C/W with no heat sink or board copper.

Check dropout separately from heat: the output sags once Vin − Vout falls below the data sheet’s dropout, which rises with load and temperature. An AMS1117 is 1.1 V typical at 0.8 A. A TLV755P in SOT-23-5 with an output from 3.3 V to below 5 V is 150 mV typical at 500 mA, with limits of 215 mV up to 85 °C and 238 mV up to 125 °C. This LDO calculator is steady state and assumes a uniform ambient: a nearby hot component, an enclosure or a short load pulse all change the answer, and short pulses can exceed the average power without damage.

Glossary

LDO
Low-dropout regulator: a linear regulator that holds its output with a small input-to-output difference.
Quiescent current (Iq)
The current the regulator draws for itself, returned to ground rather than delivered to the load.
Dropout voltage
The smallest input-to-output difference at which the output is still in regulation.
Junction temperature (TJ)
The temperature of the silicon, which is what the ratings apply to.
RθJA
Junction-to-ambient thermal resistance in °C/W. It depends on the board as well as the package.
Thermal shutdown
An internal protection that turns the output off when the junction gets too hot.

Related guides

Frequently asked questions

How do you calculate LDO power dissipation?

The LDO power loss calculation uses PD = (Vin − Vout) × Iout + Vin × Iq. The first term is the voltage the regulator drops times the load current, and the second is the input voltage times the quiescent (ground) current. Use the highest input the regulator will actually see.

How much power does a 5 V to 3.3 V LDO dissipate at 1 A?

1.73 W with a 5 mA quiescent current: 1.7 V × 1 A plus 5 V × 5 mA. An LDO at this load burns about a third of its input power as heat.

How much current can a SOT-223 LDO deliver?

It depends on the voltage drop and the copper. From 5 V to 3.3 V at 25 °C ambient, a SOT-223 on a JEDEC board (61.6 °C/W) reaches the 125 °C limit at 940 mA. On a minimum pad (136 °C/W) it reaches it at only 418 mA.

Does the quiescent current matter?

A bipolar 1117-style regulator draws about 5 mA, which is a few percent of the heat at full load but can be most of it at light load. A modern CMOS LDO with tens of microamps is negligible at any load. It matters most at high input voltage and light load, where Vin × Iq can exceed the load term.

What is the maximum junction temperature of an LDO?

Most LDOs are rated for continuous operation up to 125 °C. Thermal shutdown is usually higher (165 °C on the TLV755P), and it protects the part but is not an operating point. Many designs derate further, as in TI SLVA118A which uses 115 °C.

Can I trust the RθJA in the data sheet?

As a comparison between packages, yes; as a prediction for your board, only roughly. TI SPRA953 says RθJA is a property of the package, PCB and environment together. The AMS1117 data sheet gives a SOT-223 range from 46 °C/W to over 90 °C/W depending on copper.

When should I use a switching regulator instead of an LDO?

When the drop is large or the current is high. An LDO’s efficiency is about Vout ÷ Vin, so 12 V to 3.3 V at 200 mA is 27 % efficient and burns 1.8 W. A buck converter wastes far less of that, at the cost of switching noise and more parts.

How do you calculate LDO efficiency?

Efficiency is Vout × Iout ÷ (Vin × (Iout + Iq)), which is about Vout ÷ Vin once the load is well above Iq. From 5 V to 3.3 V at 500 mA with 5 mA of Iq it is 65 %, and this LDO efficiency calculator lists the figure next to the junction temperature.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac