Inrush current calculator

Uncharged input capacitors draw a large current the moment power is applied. This inrush current calculator finds the peak, the series resistor or NTC that limits it, and the soft-start ramp that keeps it under a target. See the charging waveforms and the energy the limiting element has to absorb.

Solve for
Examples
Input
V
F
Ω

Source, wiring, connector and switch.

Ω

Optional: adds to the series resistance.

H

Optional: a twin wire pair is about 0.5 to 1 µH per meter of cable.

Peak inrush current

120 A

Total series resistance
100 mΩ
Time constant RC
100 µs
Time to 99 % charged
461 µs
Peak power in the resistance
1.44 kW
Energy in the series element
72 mJ ½ C V²
Capacitor voltage and inrush current
0246810120204060801001200100µ200µ300µ400µ500µTime (s)Capacitor voltage (V)Current (A)
Capacitor voltageCurrent

What is the capacitor inrush current formula?

With no soft-start, Ipk = V ÷ R, where R is all the series resistance from source to capacitor including ESR. 12 V with 0.1 Ω gives 120 A, decaying with a time constant of 100 µs for 1 mF. With a controlled ramp, I = C × dV/dt plus the load. With no load drawn during the charge, the series element absorbs ½ C V²: 72 mJ in this example.

How to calculate inrush current

The inrush current formula starts from one fact: an uncharged capacitor looks like a short at the instant power is applied, so only the series resistance limits the current.

Ipk = V ÷ R     i(t) = (V ÷ R) × e^(−t/τ)     τ = R × C
V
supply voltage, or line crest for AC: Vrms × (1 + tolerance) × √2
R
total series resistance including capacitor ESR
C
total capacitance
τ
time constant RC

Charging from a fixed voltage dissipates as much energy in the series element as the capacitor stores, independent of R:

E = ½ × C × V²

With inductance L in the path, the same step drives a series RLC, which changes the inrush current equation. For ζ below 1 the current and capacitor voltage peak at:

Ipk = V × √(C ÷ L) × e^(−α tp)     Vcap = V × (1 + e^(−α π ÷ ωd))
ω₀
1 ÷ √(LC)
α
R ÷ (2L)
ωd
√(ω₀² − α²)
tp
arctan(ωd ÷ α) ÷ ωd, the time of the current peak

For a linear soft-start ramp of time tr, with the load drawn from the start:

I = C × V ÷ tr + Iload     E = ½ C V² + ½ Iload × V × tr
tr
ramp time from 0 V to full voltage
Iload
load current during the ramp

Inrush current calculation examples

Example 1: hot-plugging 1000 µF at 12 V

With 0.1 Ω of total series resistance the peak is 12 ÷ 0.1 = 120 A. The time constant is 100 µs and the capacitor is 99 % charged in 461 µs. The resistance absorbs 72 mJ.

Example 2: Ametherm’s NTC for a 110 V line

A 110 V line with +10 % tolerance has a crest of 171.1 V. Into 5 mF, the energy is 73.2 J. Limiting to 30 A takes 5.7 Ω, or 7.96 Ω at 25 °C using the 0.717 coefficient at 35 °C from the R/T curve. Ametherm then picks a 10 Ω, 250 J part.

Example 3: TI’s load switch example

3.3 V into 22 µF with a 600 mA limit needs a rise time of at least 121 µs. TI selects the TPS22902B with a typical 146 µs rise time, where the formula gives 497 mA and the measured peak was 392 mA. The pass element absorbs 120 µJ.

Energy absorbed while charging

½ C V², the energy the series resistor, NTC or pass FET must absorb. 170 V and 325 V are the crests of 120 V and 230 V AC lines.

C \ V5 V12 V24 V48 V170 V325 V
10 µF125 µJ720 µJ2.88 mJ11.5 mJ145 mJ528 mJ
100 µF1.25 mJ7.2 mJ28.8 mJ115 mJ1.45 J5.28 J
470 µF5.88 mJ33.8 mJ135 mJ541 mJ6.79 J24.8 J
1 mF12.5 mJ72 mJ288 mJ1.15 J14.5 J52.8 J
4.7 mF58.7 mJ338 mJ1.35 J5.41 J67.9 J248 J

Soft-start time for a 1 A limit

t = C V ÷ I with no load during the ramp. Scale inversely for other limits: 2 A takes half the time.

C \ V3.3 V5 V12 V24 V48 V
10 µF33 µs50 µs120 µs240 µs480 µs
100 µF330 µs500 µs1.2 ms2.4 ms4.8 ms
470 µF1.55 ms2.35 ms5.64 ms11.3 ms22.6 ms
1 mF3.3 ms5 ms12 ms24 ms48 ms
4.7 mF15.5 ms23.5 ms56.4 ms113 ms226 ms

What limits the real circuit

The peak from the simple formula is an upper bound for the given R, but R itself is often smaller than expected: electrolytic ESR falls as the capacitor warms, connector resistance is in milliohms, and regulated supplies with a current limit do not behave like a voltage step at all. Measure with a current probe when the margin is tight.

For a pass FET, the energy alone is not the check. A linear MOSFET sees full voltage and full current together, so read the safe operating area at the ramp time, derated for case temperature. TI’s hot swap note points out that many low-Rds(on) MOSFETs do not have constant-power SOA curves, so check the curve at your duration. Datasheet rise times are often 10 % to 90 %, so the full ramp takes about 1.25 times as long. TI’s load-switch example measured less current than the formula predicts.

A fixed resistor wastes I²R all the time unless a relay or FET shorts it out once the capacitors are charged. An NTC avoids that, but is sensitive to ambient temperature and to quick restarts. When an NTC drops out on a relay, it should still be rated for the steady-state current in case the relay fails, as Ametherm points out.

Glossary

Inrush current
The current drawn when power is applied, mostly into uncharged capacitors, and larger than the steady operating current.
Hot plug
Connecting a capacitive load to a supply that is already on.
NTC thermistor
A resistor that falls in value as it heats, so it limits current when cold and then drops out of the way.
Soft-start
A controlled ramp of the output voltage that sets the capacitor charging current by dV/dt.
ESR
Equivalent series resistance of a capacitor, part of the resistance limiting the peak.
Safe operating area (SOA)
The voltage, current and time combinations a MOSFET can survive, shown on a datasheet chart.

Related guides

Frequently asked questions

How do you calculate inrush current?

For a capacitor connected straight to a supply, the peak is the voltage divided by every resistance in the path: Ipk = V ÷ (Rsource + Rwiring + ESR). 12 V with 0.1 Ω of total resistance gives 120 A, whatever the capacitance. The capacitance sets how long the current lasts.

How much energy does the inrush limiting resistor absorb?

Half of C V², the same as the energy stored in the capacitor, regardless of the resistor’s value. 1 mF at 12 V puts 72 mJ in the resistor.

How do I size an NTC inrush current limiter?

Ametherm’s method takes R = Vpeak ÷ Ilimit and E = ½ C Vpeak². Their 110 V example with 5000 µF and a 30 A limit needs 5.7 Ω, or 7.96 Ω at 25 °C after derating for a 35 °C ambient, and an energy rating above 73.2 J.

Does a slower soft-start lower the energy in the pass FET?

No. With no load on during the ramp, charging the capacitor costs the FET ½ C V² whatever the ramp time, 541 mJ for 470 µF at 48 V, and a load drawn during the ramp adds ½ × Iload × V × tr, so a slower ramp then costs more. A slower ramp does lower the power and spread the energy over a longer time, which is what the safe operating area allows.

How long should a soft-start take?

Long enough that C × V ÷ t plus the load stays under your limit. For 22 µF at 3.3 V and 600 mA, that is 121 µs, the figure TI gets in SLVA670A.

Why does the capacitor voltage overshoot on a long cable?

The cable inductance and the capacitor form a resonant circuit. With little resistance, the capacitor rings to almost twice the supply: 42.7 V for a 24 V step through 1 µH and 50 mΩ into 10 µF. Low-ESR ceramics are the most exposed, and the calculator shows this when you enter an inductance.

Why does an NTC not protect against a quick power cycle?

An NTC limits inrush only while it is cold. After a quick off and on, it has not cooled, so its resistance is still low and the peak is much higher. Use a resistor with a relay or FET bypass if this matters.

How does a precharge resistor calculation work?

A precharge resistor is a series limiter that a relay or FET shorts out once the capacitors are charged. R = Vpeak ÷ Ilimit, and it absorbs ½ C V² on every charge: 171.1 V into 5 mF with a 30 A limit takes 5.7 Ω and 73.2 J. Use the Limiting resistor tab as a precharge resistor calculator.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac

Free to start. No card required.