What is the capacitor inrush current formula?
With no soft-start, Ipk = V ÷ R, where R is all the series resistance from source to capacitor including ESR. 12 V with 0.1 Ω gives 120 A, decaying with a time constant of 100 µs for 1 mF. With a controlled ramp, I = C × dV/dt plus the load. With no load drawn during the charge, the series element absorbs ½ C V²: 72 mJ in this example.
How to calculate inrush current
The inrush current formula starts from one fact: an uncharged capacitor looks like a short at the instant power is applied, so only the series resistance limits the current.
Ipk = V ÷ R i(t) = (V ÷ R) × e^(−t/τ) τ = R × C
- V
- supply voltage, or line crest for AC: Vrms × (1 + tolerance) × √2
- R
- total series resistance including capacitor ESR
- C
- total capacitance
- τ
- time constant RC
Charging from a fixed voltage dissipates as much energy in the series element as the capacitor stores, independent of R:
With inductance L in the path, the same step drives a series RLC, which changes the inrush current equation. For ζ below 1 the current and capacitor voltage peak at:
Ipk = V × √(C ÷ L) × e^(−α tp) Vcap = V × (1 + e^(−α π ÷ ωd))
- ω₀
- 1 ÷ √(LC)
- α
- R ÷ (2L)
- ωd
- √(ω₀² − α²)
- tp
- arctan(ωd ÷ α) ÷ ωd, the time of the current peak
For a linear soft-start ramp of time tr, with the load drawn from the start:
I = C × V ÷ tr + Iload E = ½ C V² + ½ Iload × V × tr
- tr
- ramp time from 0 V to full voltage
- Iload
- load current during the ramp
Inrush current calculation examples
Example 1: hot-plugging 1000 µF at 12 V
With 0.1 Ω of total series resistance the peak is 12 ÷ 0.1 = 120 A. The time constant is 100 µs and the capacitor is 99 % charged in 461 µs. The resistance absorbs 72 mJ.
Example 2: Ametherm’s NTC for a 110 V line
A 110 V line with +10 % tolerance has a crest of 171.1 V. Into 5 mF, the energy is 73.2 J. Limiting to 30 A takes 5.7 Ω, or 7.96 Ω at 25 °C using the 0.717 coefficient at 35 °C from the R/T curve. Ametherm then picks a 10 Ω, 250 J part.
Example 3: TI’s load switch example
3.3 V into 22 µF with a 600 mA limit needs a rise time of at least 121 µs. TI selects the TPS22902B with a typical 146 µs rise time, where the formula gives 497 mA and the measured peak was 392 mA. The pass element absorbs 120 µJ.
Energy absorbed while charging
½ C V², the energy the series resistor, NTC or pass FET must absorb. 170 V and 325 V are the crests of 120 V and 230 V AC lines.
| C \ V | 5 V | 12 V | 24 V | 48 V | 170 V | 325 V |
|---|
| 10 µF | 125 µJ | 720 µJ | 2.88 mJ | 11.5 mJ | 145 mJ | 528 mJ |
| 100 µF | 1.25 mJ | 7.2 mJ | 28.8 mJ | 115 mJ | 1.45 J | 5.28 J |
| 470 µF | 5.88 mJ | 33.8 mJ | 135 mJ | 541 mJ | 6.79 J | 24.8 J |
| 1 mF | 12.5 mJ | 72 mJ | 288 mJ | 1.15 J | 14.5 J | 52.8 J |
| 4.7 mF | 58.7 mJ | 338 mJ | 1.35 J | 5.41 J | 67.9 J | 248 J |
Soft-start time for a 1 A limit
t = C V ÷ I with no load during the ramp. Scale inversely for other limits: 2 A takes half the time.
| C \ V | 3.3 V | 5 V | 12 V | 24 V | 48 V |
|---|
| 10 µF | 33 µs | 50 µs | 120 µs | 240 µs | 480 µs |
| 100 µF | 330 µs | 500 µs | 1.2 ms | 2.4 ms | 4.8 ms |
| 470 µF | 1.55 ms | 2.35 ms | 5.64 ms | 11.3 ms | 22.6 ms |
| 1 mF | 3.3 ms | 5 ms | 12 ms | 24 ms | 48 ms |
| 4.7 mF | 15.5 ms | 23.5 ms | 56.4 ms | 113 ms | 226 ms |
What limits the real circuit
The peak from the simple formula is an upper bound for the given R, but R itself is often smaller than expected: electrolytic ESR falls as the capacitor warms, connector resistance is in milliohms, and regulated supplies with a current limit do not behave like a voltage step at all. Measure with a current probe when the margin is tight.
For a pass FET, the energy alone is not the check. A linear MOSFET sees full voltage and full current together, so read the safe operating area at the ramp time, derated for case temperature. TI’s hot swap note points out that many low-Rds(on) MOSFETs do not have constant-power SOA curves, so check the curve at your duration. Datasheet rise times are often 10 % to 90 %, so the full ramp takes about 1.25 times as long. TI’s load-switch example measured less current than the formula predicts.
A fixed resistor wastes I²R all the time unless a relay or FET shorts it out once the capacitors are charged. An NTC avoids that, but is sensitive to ambient temperature and to quick restarts. When an NTC drops out on a relay, it should still be rated for the steady-state current in case the relay fails, as Ametherm points out.
Glossary
- Inrush current
- The current drawn when power is applied, mostly into uncharged capacitors, and larger than the steady operating current.
- Hot plug
- Connecting a capacitive load to a supply that is already on.
- NTC thermistor
- A resistor that falls in value as it heats, so it limits current when cold and then drops out of the way.
- Soft-start
- A controlled ramp of the output voltage that sets the capacitor charging current by dV/dt.
- ESR
- Equivalent series resistance of a capacitor, part of the resistance limiting the peak.
- Safe operating area (SOA)
- The voltage, current and time combinations a MOSFET can survive, shown on a datasheet chart.
Frequently asked questions
How do you calculate inrush current?
For a capacitor connected straight to a supply, the peak is the voltage divided by every resistance in the path: Ipk = V ÷ (Rsource + Rwiring + ESR). 12 V with 0.1 Ω of total resistance gives 120 A, whatever the capacitance. The capacitance sets how long the current lasts.
How much energy does the inrush limiting resistor absorb?
Half of C V², the same as the energy stored in the capacitor, regardless of the resistor’s value. 1 mF at 12 V puts 72 mJ in the resistor.
How do I size an NTC inrush current limiter?
Ametherm’s method takes R = Vpeak ÷ Ilimit and E = ½ C Vpeak². Their 110 V example with 5000 µF and a 30 A limit needs 5.7 Ω, or 7.96 Ω at 25 °C after derating for a 35 °C ambient, and an energy rating above 73.2 J.
Does a slower soft-start lower the energy in the pass FET?
No. With no load on during the ramp, charging the capacitor costs the FET ½ C V² whatever the ramp time, 541 mJ for 470 µF at 48 V, and a load drawn during the ramp adds ½ × Iload × V × tr, so a slower ramp then costs more. A slower ramp does lower the power and spread the energy over a longer time, which is what the safe operating area allows.
How long should a soft-start take?
Long enough that C × V ÷ t plus the load stays under your limit. For 22 µF at 3.3 V and 600 mA, that is 121 µs, the figure TI gets in SLVA670A.
Why does the capacitor voltage overshoot on a long cable?
The cable inductance and the capacitor form a resonant circuit. With little resistance, the capacitor rings to almost twice the supply: 42.7 V for a 24 V step through 1 µH and 50 mΩ into 10 µF. Low-ESR ceramics are the most exposed, and the calculator shows this when you enter an inductance.
Why does an NTC not protect against a quick power cycle?
An NTC limits inrush only while it is cold. After a quick off and on, it has not cooled, so its resistance is still low and the peak is much higher. Use a resistor with a relay or FET bypass if this matters.
How does a precharge resistor calculation work?
A precharge resistor is a series limiter that a relay or FET shorts out once the capacitors are charged. R = Vpeak ÷ Ilimit, and it absorbs ½ C V² on every charge: 171.1 V into 5 mF with a 30 A limit takes 5.7 Ω and 73.2 J. Use the Limiting resistor tab as a precharge resistor calculator.
More free PCB tools
See all free electronics tools →
- Transformer calculatorTurns ratio, secondary voltage and current, reflected impedance and VA rating for an ideal transformer.
- LM317 calculatorOutput voltage of an LM317 from R1 and R2, or the standard resistor pair for a voltage, with dropout and heat.
- Power factor calculatorReal, reactive and apparent power and power factor, and the capacitor that corrects it to a target power factor.
- Wire voltage drop calculatorVoltage drop and power loss along a cable from its gauge, length, current and material, and the gauge that keeps drop in budget.
- 3 phase power calculatorReal, apparent and reactive power, line and phase current for three-phase star or delta loads.
- Supercapacitor calculatorHold-up time of a supercapacitor at constant power or current between two voltages, including ESR drop, or the size you need.
Design the whole board, not one number