Wire voltage drop calculator

Give this voltage drop calculator the size, length, current and temperature of a DC, single-phase or three-phase cable and it returns the drop, the load voltage and the power lost. Or give it a budget and find the smallest AWG or metric wire that stays within it.

Solve for
Examples
Circuit
V

Line-to-line for three-phase.

A
Length unit
m

Source to load. The return path is added for you.

Wire sizes
Conductor
°C

A warm cable has more resistance. NEC tables use 75 °C.

Voltage drop

828.1 mV

Drop
6.9 %
Voltage at the load
11.17 V
Power lost in the cable
8.28 W
Power delivered
111.7 W
Cable efficiency
93.1 %
Resistance of one conductor
41.4 mΩ
Resistance
8.281 Ω/km

Same run with other wire sizes

WireDropPercentAt loadPower lost
17 AWG1.66 V13.8 %10.34 V16.6 W
16 AWG1.32 V11 %10.68 V13.2 W
15 AWG1.04 V8.7 %10.96 V10.4 W
14 AWG828 mV6.9 %11.17 V8.28 W
13 AWG656 mV5.47 %11.34 V6.56 W
12 AWG521 mV4.34 %11.48 V5.21 W
11 AWG414 mV3.45 %11.59 V4.14 W

How do you calculate voltage drop in a wire?

Use Vd = 2 × I × L × R for DC and single-phase circuits, with L the one-way length and R the resistance per unit length. 10 A through 5 m of 14 AWG copper (8.281 Ω/km at 20 °C) drops 828 mV, or 6.9 % of a 12 V supply, and the cable dissipates 8.28 W. For balanced three-phase, replace the 2 with √3.

Voltage drop formula

The drop is the load current times the resistance of the conductors it flows through. The multiplier counts those conductors.

DC and single-phase: Vd = 2 × I × L × z     Three-phase: Vd = √3 × I × L × z
Vd
voltage drop in V (line-to-line for three-phase)
I
load current in A
L
one-way length in km
z
R for DC, or R cos φ + X sin φ for AC, in Ω/km

Schneider Electric’s Electrical Installation Guide gives the same expression for single-phase and balanced three-phase cables in its Figure G29. The term R cos φ + X sin φ comes from the phasor sum of source voltage, load voltage and the current through the cable’s R + jX. The part of the drop in quadrature with the load voltage is left out, which changes the magnitude very little while the drop is small. With power factor 1 and no reactance the formula is purely resistive.

R (Ω/km) = (1000 × ρ20 / A) × (1 + α20 × (T − 20))
ρ20
1/58 Ω·mm²/m for annealed copper, 0.028264 for EC-H19 aluminum
α20
0.00393 per °C for copper, 0.00403 for aluminum
A
cross-section in mm²

The percentage is Vd ÷ source voltage. Power lost is 2 × I² × R × L for two conductors and 3 × I² × R × L for three-phase.

How to calculate voltage drop: worked examples

Example 1: 5 A LED strip on 5 m of 18 AWG at 12 V

18 AWG copper is 20.95 Ω/km at 20 °C. Vd = 2 × 5 × 0.005 × 20.95 = 1.05 V, or 8.73 %. The strip sees 10.95 V and the cable burns 5.24 W. That much drop shows up on an unregulated strip as dimming at the far end, so a thicker feed or a second feed point is worthwhile.

Example 2: smallest wire for 20 A, 10 m at 24 V, 3 % budget

The budget allows 720 mV, so R must be below 720 mV ÷ (2 × 20 A × 0.01 km) = 1.8 Ω/km. The first gauge under that is 7 AWG, at 1.634 Ω/km, which drops 654 mV (2.72 %) and dissipates 13.1 W.

Example 3: 25 A three-phase motor, 80 m of 6 mm²

Stranded copper at 70 °C is 3.507 Ω/km. At power factor 0.85, Vd = √3 × 25 × 0.08 × 3.507 × 0.85 = 10.3 V, which is 2.58 % of 400 V. The three conductors dissipate 526 W.

Voltage drop chart by wire gauge

DC, 10 A over a 10 m one-way run of copper at 20 °C (20 m of conductor). Scale the drop and the loss linearly with length; the drop scales linearly with current and the loss with its square.

AWGAreaResistanceDropCable loss
4/0 AWG107.2 mm²0.1608 Ω/km32.2 mV322 mW
2/0 AWG67.43 mm²0.2557 Ω/km51.1 mV511 mW
1/0 AWG53.49 mm²0.3223 Ω/km64.5 mV645 mW
2 AWG33.62 mm²0.5128 Ω/km103 mV1.03 W
4 AWG21.15 mm²0.8152 Ω/km163 mV1.63 W
6 AWG13.3 mm²1.297 Ω/km259 mV2.59 W
8 AWG8.367 mm²2.061 Ω/km412 mV4.12 W
10 AWG5.261 mm²3.277 Ω/km655 mV6.55 W
12 AWG3.308 mm²5.212 Ω/km1.04 V10.4 W
14 AWG2.082 mm²8.281 Ω/km1.66 V16.6 W
16 AWG1.308 mm²13.19 Ω/km2.64 V26.4 W
18 AWG0.8229 mm²20.95 Ω/km4.19 V41.9 W
20 AWG0.5189 mm²33.23 Ω/km6.65 V66.5 W
22 AWG0.3243 mm²53.16 Ω/km10.6 V106 W
24 AWG0.2047 mm²84.22 Ω/km16.8 V168 W
26 AWG0.1281 mm²134.6 Ω/km26.9 V269 W

Longest run for a 3 % drop at 10 A

One-way length in meters for DC or single-phase at 20 °C on copper. Multiply by 3.281 for feet. Length scales inversely with current.

AWG5 V12 V24 V48 V120 V
2 AWG14.6 m35.1 m70.2 m140 m351 m
4 AWG9.2 m22.1 m44.2 m88.3 m221 m
6 AWG5.78 m13.9 m27.8 m55.5 m139 m
8 AWG3.64 m8.74 m17.5 m34.9 m87.4 m
10 AWG2.29 m5.49 m11 m22 m54.9 m
12 AWG1.44 m3.45 m6.91 m13.8 m34.5 m
14 AWG0.906 m2.17 m4.35 m8.69 m21.7 m
16 AWG0.569 m1.37 m2.73 m5.46 m13.7 m
18 AWG0.358 m0.859 m1.72 m3.44 m8.59 m
20 AWG0.226 m0.542 m1.08 m2.17 m5.42 m

Where the simple model stops

The calculation assumes the current stays fixed. A switching regulator draws more current as its input sags, so near its minimum input a real drop is worse than computed. Connectors, fuses and crimps add resistance that the cable table does not count, and at low voltage they can matter as much as the wire. Use a realistic conductor temperature: a cable near its rating runs far above 20 °C. Voltage drop and heating are separate limits, so a wire that passes this check still needs an ampacity check. Metric sizes use the nominal area: IEC 60228 also sets resistance limits for each size and a real cable can measure higher, so take the resistance from the data sheet when the budget is tight. For large AC cables, enter the reactance from the data sheet, and treat the DC resistance as a lower bound because skin and proximity effects raise the AC value.

Glossary

Voltage drop
The voltage lost along the conductors between the source and the load.
One-way length
The cable distance from source to load, not counting the return conductor.
k-factor
Resistance of a conductor one circular mil in area and one foot long: 12.9 for copper and 21.2 for aluminum at 75 °C in NEC practice.
Power factor
cos φ, where φ is the angle between load voltage and current. Motors typically run below 1.
Reactance (X)
The inductive part of a cable’s AC impedance. It depends mainly on conductor spacing, and matters most for large cables.
Line-to-line voltage
The voltage between two phases of a three-phase system, 400 V in a 230/400 V supply.

Related guides

Frequently asked questions

What is the formula for voltage drop in a wire?

For DC and single-phase AC, the voltage drop equation is Vd = 2 × I × L × R, where L is the one-way length and R is the resistance per unit length: the 2 covers the out and back conductors. For balanced three-phase, the 2 becomes √3, and Vd is the line-to-line drop.

Is the cable length one way or round trip?

Enter the one-way distance from source to load. The calculator adds the return path, so 5 m of cable means 10 m of conductor in a DC or single-phase circuit.

How much voltage drop is acceptable?

It depends on what the load tolerates. The NEC mentions voltage drop for most circuits only in informational notes, which are not mandatory, and the IAEI describes 5 % as the maximum generally suggested for a circuit; 3 % is a common design target. Low-voltage electronics often need less, so work back from the load’s minimum input voltage.

What is the voltage drop for 10 A over 5 m of 14 AWG?

828 mV at 20 °C, which is 6.9 % of a 12 V supply. The cable dissipates 8.28 W.

Does wire temperature change voltage drop?

Yes. Copper’s resistance rises about 0.393 % per °C from 20 °C, so a conductor at 75 °C has 1.216 times the 20 °C resistance. NEC table values are quoted at 75 °C for that reason.

Why is the three-phase multiplier √3 and not 2?

In a balanced three-phase circuit the phase currents sum to zero, so no current returns on a neutral and each line drops I × R to its load. Line-to-line voltage is the difference of two phases 120° apart, which is √3 times the per-phase drop.

How do I reduce voltage drop?

Use a thicker wire, shorten the run, raise the supply voltage so the same power needs less current, or run conductors in parallel. Doubling the voltage at constant power halves the current and cuts the percentage drop to a quarter.

Does this work as a volt drop calculator or a voltage loss calculator?

Yes. Volt drop, voltage loss and voltage drop all name the voltage lost along the conductors between the source and the load. The cable’s power loss is shown next to it.