How long will a supercapacitor power a load?
For a regulator load, t = C(V1² − V2²) ÷ (2P). A 10 F cell discharged from 3 V to 1 V into a 1 W load through a 90 % converter draws 1.11 W and lasts 36 s, or 35.5 s once its 26 mΩ ESR is included. For a constant current I, t = C(V1 − V2 − I × ESR) ÷ I. Allow for 30 % less capacitance and double the ESR at end of life.
Supercapacitor discharge and hold-up time formulas
The model behind this supercapacitor discharge calculator is an ideal capacitor in series with a fixed resistance. V1 is the charged voltage before the load connects, and V2 is the minimum voltage at the terminals.
Constant current: t = C × (V1 − V2 − I × R) ÷ I
- t
- hold-up time in s
- C
- pack capacitance in F
- I
- load current in A
- R
- pack ESR in Ω
That is Eaton’s Vdrop = I(R + t/C) rearranged for t, with the total drop set to V1 − V2.
Constant power, no ESR: t = C × (V1² − V2²) ÷ (2 × P)
- P
- power drawn from the capacitor in W: load power ÷ converter efficiency
With ESR, the load current follows from P = Vt × I and Vt = Vc − I × R, where Vc is the internal capacitor voltage. Integrating C dVc = −I dt gives a closed form with no time-stepping:
t = C ÷ (2P) × { (V1² − Ve²) ÷ 2 + ½ [ V1 s(V1) − Ve s(Ve) − a² ln((V1 + s(V1)) ÷ (Ve + s(Ve))) ] }
- a²
- 4 × R × P
- s(V)
- √(V² − a²)
- Ve
- internal voltage at the end: V2 + P × R ÷ V2
The load can only draw power P while Vc is at least 2√(R × P), which is the same limit as the data sheet figure P = V² ÷ (4 × ESR). The calculator stops there if your minimum voltage is lower. For a pack, C = C cell × strings ÷ cells in series and R = R cell × cells in series ÷ strings.
Hold-up capacitor calculation examples
Example 1: Eaton TV1030, 10 F, 1 W boost output
The capacitor supplies 1.11 W at 90 % efficiency. The ideal formula gives 10 × (9 − 1) ÷ (2 × 1.111) = 36 s. With 26 mΩ of ESR the terminals step to 2.99 V when the load connects, the internal voltage ends at 1.029 V, and the hold-up is 35.5 s. Current grows from 372 mA to 1.11 A at the end of the discharge.
Example 2: RTC reserve from a 3.3 F cell
At 100 µA the ESR drop is only 7.5 µV, so t = 3.3 × 1.2 ÷ 0.0001 = 11.0 hours (39.6 ks). Leakage now matters: adding Eaton’s nominal 15 µA shortens that to 9.6 hours, and leakage rises with temperature.
Example 3: sizing a five-cell pack for 30 W for 60 s
Five cells at 3.2 mΩ give 16 mΩ. At 90 % efficiency the pack supplies 33.3 W, and the formula gives 37.7 F from 12 V to 6 V. Allowing for 2 × ESR and a 30 % capacitance loss raises it to 54.7 F for the pack, or 274 F per cell. At 12 V the cells share an average of 2.4 V, but a ±20 % capacitance spread with no balancing would put 3.27 V on the smallest one, above a 2.7 V rating.
Data sheet figures for common cells
Rated values, computed energy and power limit, and a single-cell hold-up at 5 W from rated voltage to 1 V including the maximum initial ESR.
| Cell | C | Rated | Max ESR | Stored energy | V²/(4 ESR) | Hold-up at 5 W |
|---|
| Eaton TV1020-3R0605-R | 6 F | 3 V | 35 mΩ | 27 J | 64.3 W | 4.36 s |
| Eaton TV1030-3R0106-R | 10 F | 3 V | 26 mΩ | 45 J | 86.5 W | 7.46 s |
| Eaton TV1840-3R0606-R | 60 F | 3 V | 13 mΩ | 270 J | 173 W | 46.4 s |
| Eaton TV1860-3R0107-R | 100 F | 3 V | 11 mΩ | 450 J | 205 W | 77.7 s |
| Maxwell BCAP0360 | 360 F | 2.7 V | 3.2 mΩ | 1.31 kJ | 570 W | 224 s |
Usable supercapacitor energy against the voltage window
The fraction of stored energy between the two voltages is 1 − (V2/V1)². It does not depend on the capacitor, so it is the first check when choosing a voltage window.
| V2 / V1 | Energy used | Energy left behind |
|---|
| 0.80 | 36.0 % | 64.0 % |
| 0.75 | 43.8 % | 56.3 % |
| 0.67 | 55.6 % | 44.4 % |
| 0.50 | 75.0 % | 25.0 % |
| 0.33 | 88.9 % | 11.1 % |
| 0.25 | 93.8 % | 6.3 % |
What the model leaves out
Capacitance and ESR are treated as constants, but real supercapacitors have a distributed structure: voltage recovers a little after a pulse, and capacitance is lower for very short pulses. ESR rises at low temperature, so check the cold case. Keep the charged voltage at or below the rating: Eaton notes that elevated voltage and temperature shorten life, and that a 10 °C rise cuts lifetime by about half. Converter efficiency usually falls at low input voltage, so use the efficiency at the low end of the window. In a series string, also protect against reverse voltage on a weak cell when the pack is fully discharged. Datasheet capacitance tolerance, often −10 to +30 %, is separate from aging.
Glossary
- Supercapacitor (EDLC)
- Most often an electric double-layer capacitor: farads of capacitance at a few volts per cell, with very low series resistance.
- ESR
- Equivalent series resistance. Maxwell measures DC ESR from the voltage drop in the first 10 ms of a constant-current discharge, and it sets the sag under load.
- Hold-up time
- How long the capacitor keeps the load running after input power is lost.
- Constant-power load
- A load behind a regulator: it draws more current as the input voltage falls, to keep its power fixed.
- Maximum power point
- The terminal voltage of half the internal voltage, where the load resistance equals ESR. Below it, more current delivers less power.
- Cell balancing
- Passive or active circuitry that keeps each cell of a series stack below its voltage rating.
Frequently asked questions
How do you calculate supercapacitor discharge time or backup time?
At constant power, t = C(V1² − V2²) ÷ (2P) for an ideal capacitor. A 10 F cell from 3 V to 1 V at 1.11 W gives 36 s; including its 26 mΩ ESR gives 35.5 s. At constant current, t = C(V1 − V2 − I × ESR) ÷ I.
Should I use constant power or constant current?
Use constant power when the load is behind a regulator or DC-DC converter, because its input current rises as the capacitor voltage falls. Use constant current for a load that draws a fixed current whatever the voltage, such as an RTC or a circuit behind an LDO.
How does ESR affect hold-up time?
ESR causes an instant voltage step when the load connects, and it wastes I²R during the discharge. It matters most for high power and when the minimum voltage is close to the start voltage. At very high power the load cannot run at all: the limit is V²/(4 × ESR).
How much of a supercapacitor’s energy can I use?
The usable fraction is 1 − (V2/V1)². Discharging to half the start voltage uses 75 % of the stored energy, and the rest stays behind because the load’s minimum voltage has been reached. The calculator above reports the energy stored, delivered, lost in ESR and left at cutoff.
How do I calculate the supercapacitor capacitance I need?
The calculation is the hold-up formula solved for C, then raised for aging. A 30 W load for 60 s through a 90 % converter from 12 V to 6 V needs 37.7 F as a new pack, or 54.7 F with the end-of-life margin.
Does this work as a supercap calculator or an ultracapacitor calculator?
Yes. Supercap and ultracapacitor are other names for the same parts, most often electric double-layer capacitors, so the same formulas apply.
How much margin should I leave for aging?
End of life is commonly defined as a 20 to 30 % capacitance loss and a doubled ESR. Eaton’s TV series allows up to 30 % and 200 % of the initial ESR, Maxwell’s BCAP0360 20 % and twice its maximum initial ESR. The calculator shows the result at C × 0.7 and ESR × 2.
Do supercapacitors in series need balancing?
Yes, unless the voltage is far below the rating. Each cell in a series string takes the same charge, so a cell with low capacitance rises fastest. Leakage differences then move the voltages further over time. Eaton suggests passive resistors passing at least 50 times the worst-case leakage, and recommends passive balancing only for packs that do not regularly charge and discharge.
Does leakage current matter?
For long hold-ups, yes. Eaton’s 3.3 F TV0820 has a nominal leakage of 15 µA after 72 hours of charging. That is small against most loads but it shortens a 100 µA RTC reserve from 11.0 to 9.6 hours.
More free PCB tools
See all free electronics tools →
- Wire voltage drop calculatorVoltage drop and power loss along a cable from its gauge, length, current and material, and the gauge that keeps drop in budget.
- 3 phase power calculatorReal, apparent and reactive power, line and phase current for three-phase star or delta loads.
- Transformer calculatorTurns ratio, secondary voltage and current, reflected impedance and VA rating for an ideal transformer.
- Power factor calculatorReal, reactive and apparent power and power factor, and the capacitor that corrects it to a target power factor.
- Online KiCad design checkerUpload a KiCad project to run KiCad 10 DRC, ERC and schematic parity, plus JLCPCB or PCBWay rules. Every finding links to its fix.
- AI circuit diagram makerDescribe a circuit in plain English and get a clean schematic with standard symbols and a checked netlist. Export SVG, PNG, PDF, KiCad or SPICE.
Sources
- Eaton, Supercapacitor applications guide (Vdrop = I × (R + t/C), balancing, temperature and lifetime)
- Abracon, Designing with Supercapacitors (constant-power sizing, end-of-life margin)
- Eaton TV Supercapacitors, Technical Data 10554 (TV series ratings, peak power formula)
- Maxwell BCAP0360 P270 S18 datasheet, document 3001963-EN.6 (ratings, power formulas, end of life, how DC ESR is measured)