Transformer calculator

A transformer calculator for the turns ratio, secondary voltage and current, primary current, VA rating and reflected impedance. Add efficiency and regulation when you are working from a real part rather than the ideal model.

Solve for
Examples
V
Load is given as
A
%

100 % is the ideal transformer.

%

Voltage rise from full load to no load, as % of full load. From the datasheet.

Secondary voltage

12 V

Turns ratio Np ÷ Ns
10
Type
Step-down
Secondary current
2 A
Primary current
200 mA ideal
Load power
24 VA
Primary VA
24 VA
Load impedance
6 Ω
Load seen at the primary
600 Ω a² × ZL
Volts per turn
120 mV

Sine waves at the rated frequency. Primary current is the load component at unity power factor; real parts add a magnetizing current, typically 1 to 5 % of rated.

Each side

PrimarySecondary
Voltage120 V12 V
Current200 mA2 A
VA24 VA24 VA
Impedance600 Ω6 Ω

How do you calculate a transformer’s secondary voltage and current?

Multiply the primary voltage by Ns ÷ Np, and divide the secondary load’s VA by the primary voltage for the primary current. A 1000:100 transformer on 120 V gives 12 V on the secondary. Loaded with 2 A, it delivers 24 VA and draws 200 mA from the primary.

Ideal transformer equations

The same flux links both windings, so each turn sees the same voltage. With no losses, power in equals power out.

a = Np ÷ Ns = Vp ÷ Vs = Is ÷ Ip
a
turns ratio Np ÷ Ns
Vp, Vs
primary and secondary RMS voltage
Ip, Is
primary and secondary RMS current

Impedance transforms by the square of the turns ratio, because voltage goes up as current goes down:

Zp = a² × ZL     a = √(Zs ÷ ZL) to match
ZL
load on the secondary
Zp
that load as seen at the primary
Zs
source impedance to be matched

The VA rating is the same on both sides for the ideal part. Efficiency η scales the primary current:

VA = Vs × Is     Ip = Vs × Is ÷ (η × Vp)

Regulation is expressed against the full-load voltage, so the loaded secondary is below the turns-ratio value:

VR% = (Vno-load − Vfull-load) ÷ Vfull-load × 100     Vfull-load = Vno-load ÷ (1 + VR% ÷ 100)

Worked examples

Example 1: 1000 turns to 100 turns on 120 V, 2 A load

The ratio is a = 1000 ÷ 100 = 10, so Vs = 120 ÷ 10 = 12 V. With 2 A on the secondary, the load is 24 VA and 6 Ω, the primary draws 200 mA, and the load looks like 600 Ω from the primary: 120 V ÷ 200 mA gives the same number.

Example 2: 230 V to 24 V, 50 VA, with real-part figures

A 24 V full-load target with 10 % regulation needs 26.4 V at no load, so the ratio is a = 8.712. With 1150 primary turns, the secondary needs 132 turns, which delivers 24 V at load. Full load is 2.08 A on the secondary and, at 90 % efficiency, 242 mA on the primary.

Example 3: matching an 8 Ω speaker to a 3.2 kΩ plate load

a = √(3200 ÷ 8) = 20, so a 20:1 transformer makes the 8 Ω speaker look like 3.2 kΩ to the amplifier.

Transformer turns ratio table: voltage, current and impedance

What a given Np ÷ Ns does to a 120 V primary and a 50 Ω secondary load. For other ratios, use the transformer turns ratio calculator at the top of the page.

Np ÷ NsSecondary from 120 VCurrent ratio Is ÷ IpImpedance ratio50 Ω load seen at primary
100:11.2 V100×10000×500 kΩ
20:16 V20×400×20 kΩ
10:112 V10×100×5 kΩ
5:124 V5×25×1.25 kΩ
2:160 V2×4×200 Ω
1:1120 V1×1×50 Ω
1:2240 V0.5×0.25×12.5 Ω
1:101.2 kV0.1×0.01×500 mΩ

Transformer current at full load for common mains voltages

Ideal turns ratio and full-load currents for common mains and secondary combinations. The VA rating tab above gives the currents for any other pair of voltages.

PrimarySecondaryVATurns ratioSecondary currentPrimary current
120 V5 V1024:12 A83.3 mA
120 V12 V2410:12 A200 mA
120 V24 V485:12 A400 mA
230 V12 V2419.17:12 A104 mA
230 V24 V509.583:12.08 A217 mA
230 V48 V1004.792:12.08 A435 mA

Where the ideal model stops

  • Secondary current flows only with a load, but the primary always draws an exciting current to set up the flux. Michigan Tech’s notes put it at about 1 to 5 % of the rated primary current.
  • Winding resistance and leakage make the secondary sag under load. The rated voltage of a small mains transformer is often quoted at full load, so with no load it reads higher: take regulation from the datasheet.
  • Flux is proportional to voltage ÷ (frequency × turns × core area), so running a 60 Hz design from 50 Hz raises the flux by 20 % and can saturate the core.
  • Turns are whole numbers, so a low-turn winding cannot hit an arbitrary ratio. Use more turns or accept the error the calculator reports.
  • Rectifier loads draw narrow pulses, so the RMS current is higher than the DC current. Hammond’s guide de-rates a bridge to 0.62 A DC per AC amp, and half-wave to 0.28 A.
  • Wideband and RF transformers follow these relations only in band. Mini-Circuits’ AN-20-002 ties the low-frequency loss to the primary inductance and the high-frequency loss to inter-winding capacitance and series inductance.
  • Mains transformers are safety-critical. Use parts certified for your isolation class rather than an arbitrary winding.

Glossary

Turns ratio (a)
Primary turns divided by secondary turns, equal to Vp ÷ Vs for an ideal transformer.
Step-down / step-up
A transformer whose secondary voltage is lower or higher than its primary voltage.
VA rating
The apparent power a transformer can deliver: RMS voltage times RMS current.
Reflected impedance
A load impedance as seen from the other winding: multiplied by a² toward the primary.
Regulation
The change in secondary voltage from no load to full load, as a percentage of the full-load voltage.
Magnetizing current
The primary current that sets up the core flux, drawn even with no load.

Related guides

Frequently asked questions

What is the transformer formula?

The ideal transformer equation is Vp ÷ Vs = Np ÷ Ns = Is ÷ Ip: voltage scales with the turns and current scales the other way. With no losses, power in equals power out, so Vp × Ip = Vs × Is.

How do you calculate a transformer turns ratio?

Divide the primary turns by the secondary turns, or equivalently the primary voltage by the secondary voltage. The transformer turns ratio formula is a = Np ÷ Ns = Vp ÷ Vs, so a 120 V to 12 V transformer is 10:1, and 230 V to 24 V is 9.583:1.

How does transformer current change from primary to secondary?

Opposite to the voltage. A 10:1 step-down transformer with 2 A in the secondary draws 200 mA from a 120 V primary, ignoring magnetizing current and losses.

What is the reflected impedance formula?

Zp = a² × ZL, where ZL is the load on the secondary and Zp is how it looks from the primary. Through a 10:1 transformer a 6 Ω load looks like 600 Ω.

What turns ratio matches 8 Ω to 3.2 kΩ?

a = √(Zs ÷ ZL) = √(3200 ÷ 8) = 20, a 20:1 output transformer. In general the impedance ratio is the square of the turns ratio.

What is the VA rating of a transformer?

The product of the RMS voltage and the RMS current it can carry. It is in VA and not watts because the winding heating depends on the current regardless of the load’s power factor. Divide VA by the secondary voltage for the full-load secondary current; the VA rating tab does it for you.

How do you calculate transformer size?

Size it by VA: multiply the secondary voltage by the full-load secondary current. A 24 V secondary at 2.08 A needs 50 VA. Allow more for a rectifier load, because its narrow current pulses raise the RMS current above the DC current.

What is transformer voltage regulation?

The rise from full load to no load, as a percentage of the full-load voltage. A secondary of 13.2 V with no load and 12 V at full load has 10 % regulation, so the turns are chosen to give the higher voltage.

Does a transformer work on DC?

No. Induced voltage depends on the rate of change of flux, so steady DC only produces a winding current limited by resistance, and can saturate the core.

What DC current can a transformer supply through a rectifier?

Often less than its AC rating, because capacitor-input loads draw narrow, high-peak pulses. Hammond’s rectifier guide gives 0.62 A DC per AC amp for a bridge, 0.28 A for half-wave and 1.00 A for a center-tap winding.