NewAI Part GeneratorFree to get started
FREE TOOL

Rise time to bandwidth calculator

A faster edge uses more of the spectrum, and this rise time to bandwidth calculator shows how much. Convert in either direction, find the knee frequency, then see how much oscilloscope bandwidth it takes to measure the edge and how long a trace can get before it needs termination.

Solve for
Examples
s
Rise time measured
ps/in

160 ps/in is Philips AN246’s nominal 50 Ω stripline. Multiply ps/mm by 25.4.

Optional: replaces the delay above with √εr ÷ c.

Critical length rule
Hz

Optional: compares the edge with the 5 × clock scope rule.

Bandwidth (−3 dB)

350 MHz

0.35 ÷ rise time

Knee frequency
500 MHz 0.5 ÷ rise time
Edge length on the line
159 mm (6.25 in) tr ÷ tpd
Critical length, tr ÷ 6
26.5 mm (1.04 in) at 160 ps/in
Scope bandwidth, 20 % error
500 MHz 1.0 × knee
Scope bandwidth, 3 % error (Gaussian)
950 MHz 1.9 × knee
Scope bandwidth, 3 % error (maximally flat)
700 MHz 1.4 × knee

0.35 assumes a single-pole or roughly Gaussian response. A maximally flat response is closer to 0.4 ÷ bandwidth (Keysight).

Critical trace length versus rise time
1101001000100p1n10nRise time (s)Critical length (mm)tr 1 ns
tr ÷ 2tr ÷ 3tr ÷ 6tr ÷ 10

Critical length under each published rule

RuleCritical lengthMeaning
tr ÷ 279.4 mm (3.13 in)Round-trip delay equals the rise time (Philips AN246). The loosest common limit; Johnson warns of severe ringing on unterminated nets at this length.
tr ÷ 352.9 mm (2.08 in)Upper end of the range in use (Johnson).
tr ÷ 626.5 mm (1.04 in)Johnson’s rule of thumb for simulating a net.
tr ÷ 1015.9 mm (0.625 in)Lower end of the range: a stiff driver and a large capacitive load (Johnson).

How do you convert rise time to bandwidth?

Use BW = 0.35 ÷ tr for a 10 to 90 % rise time. A 1 ns edge corresponds to 350 MHz. The knee frequency, 0.5 ÷ tr, is 500 MHz, and that is the figure to use when choosing a scope. On a 160 ps/in line the edge is 159 mm (6.25 in) long, and Howard Johnson’s rule of thumb for simulating a net is anything over one sixth of that, 26.5 mm (1.04 in).

Rise time-bandwidth formula, knee frequency and critical length

Rise time and bandwidth are two views of the same low-pass response. The knee frequency describes the signal rather than the system, and the critical length compares the edge with the delay of the line.

BW = 0.35 ÷ tr (10–90 %)     BW = 0.22 ÷ tr (20–80 %)
BW
−3 dB bandwidth in Hz
tr
rise time in s
fknee
knee frequency in Hz

These assume a single-pole or roughly Gaussian response. Keysight puts a maximally flat response at about 0.4 ÷ BW. The knee frequency formula comes from Johnson and Graham:

fknee = 0.5 ÷ tr (10–90 %)     fknee = 0.4 ÷ tr (20–80 %)

The edge occupies a length of line set by the delay per unit length. Critical length is a fraction of that:

edge length = tr ÷ tpd     critical length = tr ÷ (k × tpd)     tpd = √εr ÷ c
tpd
propagation delay per unit length
k
2 (Philips AN246, round trip equals the rise time) to 10 (conservative); Johnson’s rule of thumb is 6
εr
effective dielectric constant of the line
c
299,792,458 m/s

Worked examples

Example 1: a 1 ns edge on a 160 ps/in line

BW = 0.35 ÷ 1 ns = 350 MHz and fknee = 0.5 ÷ 1 ns = 500 MHz. The edge is 159 mm (6.25 in) long. Johnson’s one-sixth rule gives 26.5 mm (1.04 in), and AN246’s round-trip rule gives 79.4 mm (3.13 in).

Example 2: choosing a scope for a 500 ps edge (Keysight’s example)

fknee = 0.5 ÷ 500 ps = 1 GHz. For 20 % timing error a 1 GHz scope is enough. For 3 %, a Gaussian scope needs 1.9 × 1 GHz = 1.9 GHz, and a maximally flat one needs 1.4 GHz.

Example 3: critical length of an ABT driver (Philips AN246)

A lightly loaded ABT output has a nominal 0.9 ns rise time, about 389 MHz. On a 160 ps/in, 50 Ω stripline, tr ÷ (2 × tpd) = 71.4 mm (2.81 in), which AN246 rounds to 2.8 in. One sixth of the edge length is shorter, 23.8 mm (0.938 in).

Rise time to bandwidth, knee and critical length table

10 to 90 % rise times on a line with 160 ps/in of delay.

Rise timeBandwidthKneeEdge lengthtr ÷ 2tr ÷ 6
50 ps7 GHz10 GHz7.94 mm (0.313 in)3.97 mm (0.156 in)1.32 mm (0.0521 in)
100 ps3.5 GHz5 GHz15.9 mm (0.625 in)7.94 mm (0.313 in)2.65 mm (0.104 in)
200 ps1.75 GHz2.5 GHz31.8 mm (1.25 in)15.9 mm (0.625 in)5.29 mm (0.208 in)
500 ps700 MHz1 GHz79.4 mm (3.13 in)39.7 mm (1.56 in)13.2 mm (0.521 in)
1 ns350 MHz500 MHz159 mm (6.25 in)79.4 mm (3.13 in)26.5 mm (1.04 in)
2 ns175 MHz250 MHz318 mm (12.5 in)159 mm (6.25 in)52.9 mm (2.08 in)
5 ns70 MHz100 MHz794 mm (31.3 in)397 mm (15.6 in)132 mm (5.21 in)
10 ns35 MHz50 MHz1.59 m (62.5 in)794 mm (31.3 in)265 mm (10.4 in)
20 ns17.5 MHz25 MHz3.18 m (125 in)1.59 m (62.5 in)529 mm (20.8 in)

Oscilloscope bandwidth needed

Keysight’s multipliers on the knee frequency, with the result for a 1 ns edge (knee 500 MHz).

Rise-time errorGaussian scopeMaximally flat scopeGaussian, 1 ns edgeMaximally flat, 1 ns edge
20 %1.0 × fknee1.0 × fknee500 MHz500 MHz
10 %1.3 × fknee1.2 × fknee650 MHz600 MHz
3 %1.9 × fknee1.4 × fknee950 MHz700 MHz

Using these numbers on a real board

Use the fastest edge your driver can produce, not the one its typical load gives. AN246 works from the faster of the rise and fall times, and a part from a newer process can be much faster than its data sheet’s maximum suggests. Critical length is not a hard edge: the published conventions span a factor of five, and the right one depends on the driver impedance, the load and whether you can wait for ringing to settle. A stiff driver into a large capacitive load is the worst case, where Johnson reports termination being needed on lines as short as a tenth of the edge length, and he warns that a line delay of half the rise time can already give severe overshoot and ringing on an unterminated net. Microstrip has part of its field in air, so its effective εr is below the laminate value and it runs faster than stripline. When in doubt, simulate the net with the driver and receiver models you intend to use.

Glossary

Rise time (tr)
The time an edge takes to go between two levels, usually 10 to 90 % of its swing. Device data increasingly quotes 20 to 80 %.
Bandwidth
The frequency where a system’s response has fallen 3 dB from its passband.
Knee frequency
The frequency above which an edge’s spectrum contributes little to its shape.
Propagation delay (tpd)
The time a signal takes to travel a unit length of line, in ps/in or ps/mm.
Edge length
How much of the line the edge occupies at one instant: tr ÷ tpd.
Critical length
The longest line that can be treated as a lumped element under a given rule, without modeling reflections.
Gaussian response
A low-pass shape with a slow roll-off, typical of scopes at 1 GHz and below.
Maximally flat response
A low-pass shape that stays flat to near its cutoff and then rolls off sharply, typical of scopes above 1 GHz.

Related guides

Frequently asked questions

What is the formula for bandwidth from rise time?

BW = 0.35 ÷ tr for a 10 to 90 % rise time, so a 1 ns edge corresponds to 350 MHz. For a 20 to 80 % rise time use 0.22 ÷ tr. Both describe a single-pole or roughly Gaussian response.

How do you calculate rise time from bandwidth?

Divide the constant by the bandwidth: tr = 0.35 ÷ BW for a 10 to 90 % rise time, or 0.22 ÷ BW for 20 to 80 %. A 100 MHz bandwidth gives 3.5 ns. This assumes a single-pole or roughly Gaussian response.

How do you convert rise time to frequency?

A 10 to 90 % edge has a bandwidth of 0.35 ÷ tr and a knee frequency of 0.5 ÷ tr, so a 1 ns edge has 350 MHz of bandwidth and a 500 MHz knee.

Where does the 0.35 in the rise time-bandwidth relationship come from?

A single-pole step response takes τ × ln 9 to go from 10 to 90 %, and its bandwidth is 1 ÷ (2πτ). Multiplying them gives ln 9 ÷ 2π = 0.3497, rounded to 0.35. Keysight gives about 0.4 for scopes with a maximally flat response.

What is the knee frequency of a digital signal?

The frequency above which the spectrum of an edge no longer has much effect on its shape: 0.5 ÷ tr for a 10 to 90 % edge and 0.4 ÷ tr for a 20 to 80 % edge. The idea comes from Johnson and Graham. A 1 ns edge has a knee of 500 MHz.

What oscilloscope bandwidth do I need to measure an edge?

Multiply the knee frequency by 1.0 for 20 % timing error, or by 1.9 (Gaussian scope) or 1.4 (maximally flat scope) for 3 %. A 500 ps edge needs 1 GHz to 1.9 GHz. Keysight says most scopes at 1 GHz and below are roughly Gaussian.

How long can a PCB trace be before it needs termination?

There is no single limit. Philips AN246 uses the point where round-trip delay equals the rise time (length = tr ÷ 2tpd). Howard Johnson reports that people terminate at between 1/10 and 1/3 of the edge length and simulates anything over about 1/6. For a 1 ns edge at 160 ps/in those limits run from 15.9 mm (0.625 in) to 79.4 mm (3.13 in).

Does clock frequency set the bandwidth a signal needs?

No, the edge rate does. A 10 MHz clock with a 500 ps edge has the same knee frequency as a 100 MHz clock with that edge. Keysight’s 5 × clock rule for scope bandwidth holds for edges that are slow compared with the clock period, and falls short for fast edges on slow clocks.

What is the rise time of a 100 MHz oscilloscope?

About 3.5 ns, from 0.35 ÷ bandwidth, for a scope with a Gaussian response. That is the fastest edge the instrument can display, not the fastest it can measure accurately.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac

Free to start. No card required.