How do you calculate PCB plane capacitance?
Use C = ε0 εr A ÷ d, with the overlapping area A in square meters and the spacing d in meters (ε0 = 8.854 pF/m). Two planes 4 mil apart in FR-4 with εr 4.5 come to 253 pF per square inch.
Parallel copper areas, power and ground plane pairs, pads over a plane and traces each have a tab in this PCB capacitance calculator. Get capacitance per unit area or length with the fringing and stackup details that decide whether the answer holds.
Finished dielectric thickness between the copper layers.
Use your laminate’s Dk.
Capacitance
1.948 nF
Assumes the copper overlaps fully, one dielectric fills the gap and the spacing is the finished dielectric thickness.
Use C = ε0 εr A ÷ d for overlapping copper: one square inch 4 mil apart in FR-4 with εr 4.5 is 253 pF. For a trace, use C′ = √εeff ÷ (c Z0), about 2.98 pF per inch for a 50 Ω microstrip. Small pads need a fringing correction, which this calculator adds.
Overlapping copper behaves as a parallel-plate capacitor. A trace is a transmission line, so its capacitance per length follows from its impedance and effective dielectric constant.
For a trace over a plane, per unit length:
Z0 and εeff come from the same models as the PCB impedance calculator: Hammerstad-Jensen (IEEE MTT-S Digest, 1980) for microstrip and Wheeler (IEEE Trans. MTT, 1978) for stripline.
For a pad over a plane, with its short side w, the fringing per unit length of edge comes from the same line model:
We checked this against a 3-D field solve of 1 oz pads on FR-4. That solve is our own numerical result, not a published one. It stays within about 5 % when the short side is at least twice the height, and within about 2 % at three times. It reads low on smaller pads, by about 12 % when the short side equals the height and 30 % at half the height. The calculator warns when a pad is in that range.
The short ends of the pad use the same fringing per unit length as the long sides, which is an approximation. A microstrip open end is the published version of the same effect, with an end capacitance of C′ × Δl for a length extension Δl. The table sets the extension our end term amounts to beside the expressions of Kirschning, Jansen and Koster and of Hammerstad, as given in the Qucs technical documentation, for 0.2 mm of εr 4.4 with 1 oz copper. For short sides of 2 to 5 heights our term is within 11 % of Kirschning. It is 21 % below at one height, consistent with the low readings above, and 23 % above at ten heights, where the ends are a small part of a large pad.
| Short side ÷ h | Model Δl ÷ h | Kirschning Δl ÷ h | Hammerstad Δl ÷ h |
|---|---|---|---|
| 1 | 0.277 | 0.349 | 0.339 |
| 2 | 0.395 | 0.409 | 0.39 |
| 3 | 0.463 | 0.446 | 0.423 |
| 5 | 0.544 | 0.489 | 0.469 |
| 10 | 0.645 | 0.523 | 0.539 |
A = 100 mm × 100 mm = 0.01 m², d = 0.2 mm, εr = 4.4. C = 8.854 pF/m × 4.4 × 0.01 ÷ 0.0002 = 1.95 nF, or 19.5 pF/cm².
The parallel-plate value is 156 fF. With the short side 4 times the height, fringing around the four edges adds about 62 %, giving 252 fF.
Hammerstad-Jensen gives Z0 = 54.5 Ω and εeff = 3.13, so C′ = √3.13 ÷ (c × 54.5 Ω) = 108 pF/m, about 2.75 pF per inch. Over 50 mm that is 5.41 pF.
C = ε0 εr A ÷ d per unit of overlapping area. Use the finished dielectric thickness from your fab’s stackup. The Plane pair tab above is a PCB plane capacitance calculator for any area, with parallel pairs and copper fill.
| Thickness | In mm | pF/in², εr 4.2 | pF/in², εr 4.5 | pF/cm², εr 4.5 |
|---|---|---|---|---|
| 2 mil | 0.0508 | 472 | 506 | 78.4 |
| 3 mil | 0.0762 | 315 | 337 | 52.3 |
| 4 mil | 0.102 | 236 | 253 | 39.2 |
| 5 mil | 0.127 | 189 | 202 | 31.4 |
| 8 mil | 0.203 | 118 | 127 | 19.6 |
| 10 mil | 0.254 | 94.5 | 101 | 15.7 |
| 20 mil | 0.508 | 47.2 | 50.6 | 7.84 |
| 40 mil | 1.02 | 23.6 | 25.3 | 3.92 |
| 60 mil | 1.52 | 15.7 | 16.9 | 2.61 |
C′ = √εeff ÷ (c Z0) for microstrip with εeff 3.1 (typical on FR-4) and stripline in εr 4.4. For your own width and height, on microstrip or stripline, use the PCB trace capacitance calculator on the Trace tab above.
| Z0 | Microstrip pF/in | Microstrip pF/mm | Stripline pF/in | Stripline pF/mm |
|---|---|---|---|---|
| 40 Ω | 3.73 | 0.147 | 4.44 | 0.175 |
| 50 Ω | 2.98 | 0.117 | 3.55 | 0.14 |
| 60 Ω | 2.49 | 0.0979 | 2.96 | 0.117 |
| 75 Ω | 1.99 | 0.0783 | 2.37 | 0.0933 |
| 100 Ω | 1.49 | 0.0587 | 1.78 | 0.07 |
The parallel-plate formula is reliable when the copper is many times wider than the dielectric is thick, and the calculator warns when it is not. Pads and short stubs are mostly edge, so use the pad mode for them and treat the figure as an estimate: a 3-D field solver settles it. Fringing in air also depends on solder mask, which is not modeled. High-impedance nodes, transimpedance inputs and fast differential pairs are where a fraction of a picofarad matters. For high-speed pairs, TI voids the reference plane under SMD mounting pads, at least two layers deep, to reduce this discontinuity. Long nets add up too: a 0.15 mm stripline with ½ oz copper and 0.2 mm of dielectric on each side has Z0 = 51.2 Ω and about 3.47 pF per inch.
Use C = ε0 εr A ÷ d, with the overlapping area A in square meters and the spacing d in meters (ε0 = 8.854 pF/m). Two planes 4 mil apart in FR-4 with εr 4.5 come to 253 pF per square inch.
253 pF per square inch (39.2 pF/cm²) at 4 mil and εr 4.5, and it scales inversely with spacing. A 100 mm square plane pair over 0.2 mm of εr 4.4 has 1.95 nF.
A 1 × 0.8 mm pad over 0.2 mm of εr 4.4 is 156 fF by the parallel-plate formula and about 252 fF once edge fringing is included. On a thin dielectric, a pad is a noticeable load for fast or high-impedance nodes.
C′ = √εeff ÷ (c Z0). A 50 Ω microstrip with εeff 3.1 has about 2.98 pF per inch, and a 50 Ω stripline in εr 4.4 about 3.55 pF per inch.
Model the copper as what it is. A pad or overlap is a parallel plate plus edge fringing (1 × 0.8 mm over 0.2 mm of εr 4.4 is about 252 fF), and a trace follows C′ = √εeff ÷ (c Z0), about 2.98 pF per inch for a 50 Ω microstrip. Pick the tab above that matches the copper.
When the narrow side of the copper is not much larger than the spacing. The 1 × 0.8 mm pad above gains about 62 % from fringing at its edges, while a plane many times wider than its spacing gains almost nothing.
Use a smaller pad, move the reference plane further away, or void the plane under the pad. TI’s high-speed layout guide voids the reference plane under SMD mounting pads on high-speed pairs, at least two layers deep.
Not on its own. Even a 100 mm square plane pair over 0.2 mm gives only 1.95 nF, far less than one 100 nF ceramic. Its value is low inductance at high frequency, alongside discrete capacitors.
See all free electronics tools →
ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.
Free to start. No card required.