How do you calculate inductors in series?
Add them, provided no flux from one links another: L = L1 + L2 + … So 10 µH and 22 µH in series make 32 µH. If the inductors are magnetically coupled, add or subtract 2M for each coupled pair.
Work out the total inductance of inductors in series and parallel, up to six at a time, or of two magnetically coupled windings aiding or opposing, from their coupling coefficient or mutual inductance. You can also find the mutual inductance from two series measurements.
Up to 6 inductors; the next field appears as you fill this one.
Total inductance (series)
32 µH
Assumes no magnetic coupling: shielded inductors, or unshielded ones spaced apart or at right angles. If flux from one links another, use the coupled pair tab.
The same current flows through every inductor in series, so each must be rated for the full current. DCR adds too.
Share of the AC voltage across each inductor
| Inductor | Value | Share |
|---|---|---|
| L1 | 10 µH | 31.3 % |
| L2 | 22 µH | 68.8 % |
Uncoupled inductors combine like resistors. In series they add: 10 µH + 22 µH = 32 µH. In parallel the reciprocals add: 10 µH ∥ 22 µH = 6.875 µH. When the fields of two inductors link, the mutual inductance M joins in: L1 + L2 ± 2M in series, plus when the fields aid and minus when they oppose.
Without magnetic coupling, inductors combine exactly like resistors: the same current through a series string, the same voltage across a parallel group.
Two coils whose fields link share a mutual inductance M, set by the coupling coefficient k (0 to 1):
In series the mutual term appears twice, once for each coil’s effect on the other. Upper signs are for aiding fields, lower signs for opposing:
The parallel form comes from writing v = L1 di1/dt ± M di2/dt = ±M di1/dt + L2 di2/dt for the shared voltage and solving for the total di/dt; Evstatiev’s lecture notes (in the sources below) work it through and give the same result, with −2M in the denominator for aiding fields and +2M for opposing. Measuring the two series connections gives M directly, and shorting one winding leaves the leakage inductance:
In series the three add to 36.7 µH. In parallel, 1/L = 1/10 + 1/22 + 1/4.7 µH⁻¹, so L = 2.792 µH, below the smallest part. Both assume no coupling, which well-shielded parts come close to.
Each winding is 4.7 µH and the typical coupling is 0.98, so M = 0.98 × 4.7 µH = 4.606 µH. In series aiding the part gives 18.61 µH, close to the datasheet’s “four times the value” (18.8 µH). In parallel aiding it gives 4.653 µH, the datasheet’s “same value”. With one winding shorted the other shows 186.1 nH, against 0.20 µH typical leakage inductance on the datasheet.
Two coils read 250 mH in series aiding and 150 mH with one reversed. M = (250 − 150) ÷ 4 = 25 mH and L1 + L2 = 200 mH. If coil 1 alone reads 150 mH, coil 2 is 50 mH and k = 25 ÷ √(150 × 50) = 0.289, a loose coupling.
Total inductance as a multiple of one inductor L, for two equal windings at different coupling coefficients. k = 0 is the uncoupled case.
| k | Series aiding | Series opposing | Parallel aiding | Parallel opposing |
|---|---|---|---|---|
| 0 | 2.000 L | 2.000 L | 0.500 L | 0.500 L |
| 0.1 | 2.200 L | 1.800 L | 0.550 L | 0.450 L |
| 0.3 | 2.600 L | 1.400 L | 0.650 L | 0.350 L |
| 0.5 | 3.000 L | 1.000 L | 0.750 L | 0.250 L |
| 0.7 | 3.400 L | 0.600 L | 0.850 L | 0.150 L |
| 0.9 | 3.800 L | 0.200 L | 0.950 L | 0.050 L |
| 0.98 | 3.960 L | 0.040 L | 0.990 L | 0.010 L |
| 1 | 4.000 L | 0.000 L | 1.000 L | 0.000 L |
L1 × L2 ÷ (L1 + L2), with no coupling. Two equal inductors in parallel give half the value.
| L1 \ L2 | 1 µH | 2.2 µH | 4.7 µH | 10 µH | 22 µH | 47 µH | 100 µH |
|---|---|---|---|---|---|---|---|
| 1 µH | 500 nH | 687.5 nH | 824.6 nH | 909.1 nH | 956.5 nH | 979.2 nH | 990.1 nH |
| 2.2 µH | 687.5 nH | 1.1 µH | 1.499 µH | 1.803 µH | 2 µH | 2.102 µH | 2.153 µH |
| 4.7 µH | 824.6 nH | 1.499 µH | 2.35 µH | 3.197 µH | 3.873 µH | 4.273 µH | 4.489 µH |
| 10 µH | 909.1 nH | 1.803 µH | 3.197 µH | 5 µH | 6.875 µH | 8.246 µH | 9.091 µH |
| 22 µH | 956.5 nH | 2 µH | 3.873 µH | 6.875 µH | 11 µH | 14.99 µH | 18.03 µH |
| 47 µH | 979.2 nH | 2.102 µH | 4.273 µH | 8.246 µH | 14.99 µH | 23.5 µH | 31.97 µH |
| 100 µH | 990.1 nH | 2.153 µH | 4.489 µH | 9.091 µH | 18.03 µH | 31.97 µH | 50 µH |
Unshielded inductors placed side by side couple through their stray fields, so the uncoupled formulas only hold for shielded parts, for parts spaced well apart, or for coils at right angles to each other. Every inductor in series carries the full current, so each needs a saturation and RMS current rating above it, and the DCRs add. Parallel inductors share AC current by inductance but DC current by DCR, so two nominally equal parts (often ±20 % in inductance) rarely split evenly; leave margin on saturation current. Inductance also falls with DC bias and rises toward the self-resonant frequency, so these totals hold at low current and well below resonance. A coupled inductor with k near 1 cannot be paralleled with mismatched windings: the turns differ, the induced voltages differ, and a large current circulates between them.
Add them, provided no flux from one links another: L = L1 + L2 + … So 10 µH and 22 µH in series make 32 µH. If the inductors are magnetically coupled, add or subtract 2M for each coupled pair.
Add the reciprocals: 1/L = 1/L1 + 1/L2 + …, or L1 × L2 ÷ (L1 + L2) for two. 10 µH and 22 µH in parallel make 6.875 µH, less than the smaller one.
It adds 2M when the fields aid and subtracts 2M when they oppose: L = L1 + L2 ± 2M. A 10 H and a 5 H coil with M = 7 H, aiding, total 29 H; opposing, only 1 H.
Yes. The Series and Parallel tabs each total up to six inductors. The Coupled pair tab adds mutual inductance for two windings.
The fraction of one coil’s flux that links the other, from 0 (no coupling) to 1 (all of it). It sets the mutual inductance: M = k √(L1 L2). Well-shielded inductors, or ones far apart, are close to 0; a two-winding coupled inductor such as the Coilcraft MSD1260 is 0.98 or higher.
Connect the two windings in series and measure, then reverse one winding and measure again; the Find M tab is the mutual inductance calculator for those two readings. M = (L aiding − L opposing) ÷ 4. Readings of 250 mH and 150 mH give M = 25 mH.
With equal windings and k close to 1, series aiding gives L + L + 2M ≈ 4L and parallel aiding gives about L. At the MSD1260’s typical k of 0.98, a 4.7 µH part gives 18.61 µH in series and 4.653 µH in parallel.
Only with care. At DC the current divides by winding resistance (DCR), not by inductance, so mismatched parts share unevenly and one can saturate first. The windings of a coupled inductor are made for it: Coilcraft specifies the same inductance and half the DCR when they are paralleled.
See all free electronics tools →
ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.
Free to start. No card required.