How do you calculate capacitors in series?
Add the reciprocals and take the reciprocal of the sum: 1/C = 1/C1 + 1/C2 + 1/C3 + … For two capacitors this is C1 × C2 ÷ (C1 + C2). The total is always smaller than the smallest capacitor in the string.
The capacitors in series and parallel calculator below takes up to eight parts and gives the total capacitance, the charge and the stored energy. For a series stack, see how a voltage splits across each capacitor, the worst case with tolerance and the balancing resistor that keeps every part within its rating.
Up to 8 capacitors; the next field appears as you fill this one.
Optional: shows charge, energy and (in series) the voltage on each capacitor.
Optional. If they differ, enter the lowest.
Optional worst case. For −10/+30 % parts enter 30.
Optional: datasheet maximum, to size balancing resistors.
Total capacitance (series)
68.75 nF
Enter the applied voltage to see how it splits across the capacitors.
Share of the voltage on each capacitor
| Capacitor | Value | Share |
|---|---|---|
| C1 | 100 nF | 68.8 % |
| C2 | 220 nF | 31.3 % |
Use 1/C = 1/C1 + 1/C2 + … , or C1 × C2 ÷ (C1 + C2) for two. A 100 nF and a 220 nF capacitor in series make 68.75 nF, less than either one. In parallel capacitances simply add (320 nF). In series every capacitor carries the same charge, so the smallest one takes the largest share of the voltage.
Capacitors combine the opposite way to resistors. In parallel the plate areas effectively add, so the total rises; in series the dielectric thicknesses effectively add, so it falls.
For two capacitors in series, the reciprocal sum simplifies to product over sum:
A series string charged from 0 V puts the same charge Q on every capacitor, so the voltage on each one is inversely proportional to its capacitance:
Held at DC, leakage current takes over the split. For n capacitors rated Umax, each leaking anywhere from 0 to Ileak, equal resistors across every capacitor keep the worst one within its rating when:
For two capacitors this is Vishay’s Rmax = (2 Umax − U) ÷ Ileak. The worst case is one capacitor that leaks nothing while the others leak the maximum; it then sits at (U + R (n − 1) Ileak) ÷ n.
In series, 1/C = 1/1 + 1/5 + 1/8 = 1.325 µF⁻¹, so C = 754.7 nF, below the smallest part. In parallel the same three make 14 µF. Across 12 V the series string splits 9.057 V, 1.811 V and 1.132 V: the 1 µF capacitor takes 75.5 % of the voltage.
Two 1 F cells in series make 500 mF and, matched, sit at 2.5 V each. Supercapacitors are commonly ±20 %, so one cell can be 0.8 F while the other is 1.2 F; the small one then charges to 3 V, above its 2.7 V rating. Even before leakage, a worst-case pair stays within that rating only up to 4.5 V. The pair stores 6.25 J at 5 V.
The Vishay 193 PUR-SI 470 µF 400 V part is ±20 % with a maximum leakage of 0.01 × CR × UR = 1.88 mA after 5 minutes. In series the pair is 235 µF. While charging, a worst-case ±20 % pair puts 420 V on one capacitor, over its rating; capacitors from one batch (Vishay quotes about ±6 %) give 371 V. At DC the balancing resistor must be at most (2 × 400 − 700) ÷ 1.88 mA = 53.2 kΩ. With the E24 value 51 kΩ, the worst capacitor sits at 397.9 V, the divider draws 6.86 mA and each resistor dissipates up to 3.11 W, which is why high-voltage banks often use active balancing instead.
C1 × C2 ÷ (C1 + C2) for common ceramic values. Two equal capacitors in series give half the value.
| C1 \ C2 | 10 nF | 22 nF | 47 nF | 100 nF | 220 nF | 470 nF | 1 µF |
|---|---|---|---|---|---|---|---|
| 10 nF | 5 nF | 6.875 nF | 8.246 nF | 9.091 nF | 9.565 nF | 9.792 nF | 9.901 nF |
| 22 nF | 6.875 nF | 11 nF | 14.99 nF | 18.03 nF | 20 nF | 21.02 nF | 21.53 nF |
| 47 nF | 8.246 nF | 14.99 nF | 23.5 nF | 31.97 nF | 38.73 nF | 42.73 nF | 44.89 nF |
| 100 nF | 9.091 nF | 18.03 nF | 31.97 nF | 50 nF | 68.75 nF | 82.46 nF | 90.91 nF |
| 220 nF | 9.565 nF | 20 nF | 38.73 nF | 68.75 nF | 110 nF | 149.9 nF | 180.3 nF |
| 470 nF | 9.792 nF | 21.02 nF | 42.73 nF | 82.46 nF | 149.9 nF | 235 nF | 319.7 nF |
| 1 µF | 9.901 nF | 21.53 nF | 44.89 nF | 90.91 nF | 180.3 nF | 319.7 nF | 500 nF |
n equal capacitors split the voltage evenly while charging, but tolerance moves the split. The worst case puts one capacitor at the low limit and the rest at the high limit.
| Capacitors | Total C | Each, matched | Worst, ±10 % | Worst, ±20 % |
|---|---|---|---|---|
| 2 | C ÷ 2 | 50.0 % | 55.0 % | 60.0 % |
| 3 | C ÷ 3 | 33.3 % | 37.9 % | 42.9 % |
| 4 | C ÷ 4 | 25.0 % | 28.9 % | 33.3 % |
| 5 | C ÷ 5 | 20.0 % | 23.4 % | 27.3 % |
| 6 | C ÷ 6 | 16.7 % | 19.6 % | 23.1 % |
The equal-charge split only holds while the stack charges. Held at DC, the capacitor with the lower leakage current drifts up toward more than its share, which is why electrolytic and supercapacitor stacks get a resistor (or an active balancer) across each capacitor. Leakage changes with temperature and age, so size the resistor from the datasheet maximum, not a typical value. Use capacitors from the same batch in one string, and if one fails, replace the whole string. Ceramic capacitors (X5R, X7R) lose a large share of their capacitance under DC bias, so their effective value at your voltage, not the marked value, sets the split. In parallel, every capacitor sees the full voltage, and the bank behaves as the sum only at frequencies where each part’s ESR and ESL are small compared with its reactance.
Add the reciprocals and take the reciprocal of the sum: 1/C = 1/C1 + 1/C2 + 1/C3 + … For two capacitors this is C1 × C2 ÷ (C1 + C2). The total is always smaller than the smallest capacitor in the string.
68.75 nF. 100 × 220 ÷ (100 + 220) = 68.75 nF. In parallel the same two capacitors make 320 nF.
Every capacitor in the string carries the same charge, so each takes V × Ctotal ÷ Ci: the smallest capacitor takes the largest share. With 1, 5 and 8 µF across 12 V the split is 9.057 V, 1.811 V and 1.132 V. That is the split while the stack charges; held at DC, leakage current sets it instead.
Electrolytic and supercapacitor stacks do, because their leakage currents differ and, held at DC, the capacitor that leaks least ends up with more than its share. Vishay sizes the resistor across each of two capacitors as Rmax = (2 Umax − U) ÷ Ileak; for two 400 V, 470 µF parts on 700 V with 1.88 mA leakage that is 53.2 kΩ.
Add them: C = C1 + C2 + C3 + … Every capacitor sees the full voltage, so each one must be rated for it, and the bank’s rating is that of the lowest-rated part.
Both. Pick series or parallel and enter up to eight capacitors for the total capacitance; add a voltage and you also get the charge and stored energy, plus the voltage on each capacitor in series.
Mainly to reach a working voltage above one part’s rating, such as 2.7 V supercapacitor cells stacked for a 5 V rail, or 400 V electrolytics on a 700 V bus. You give up capacitance: n equal capacitors in series have 1/n of the capacitance of one.
The same capacitors store the same energy at their own voltage however they are connected. Two 1 F cells at 2.5 V each hold 3.125 J apiece; in series as 500 mF at 5 V they hold 6.25 J in total.
See all free electronics tools →
ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.
Free to start. No card required.