NewAI Part GeneratorFree to get started
FREE TOOL

Resistor tolerance calculator with TCR

This resistor tolerance calculator gives the lowest and highest value a resistor can take from its tolerance, its temperature coefficient (TCR) and any extra drift over your operating temperature range. Or work backwards to the TCR an error budget allows.

Solve for
Examples
Ω
%

± at the reference temperature, e.g. 1 for ±1 %.

TCR is
ppm/°C

ppm/°C and ppm/K are the same number.

°C

Where the tolerance is specified: see the datasheet (often 20 °C or 25 °C).

°C
°C
%

Load life or soldering heat from the datasheet, e.g. 1 for ±1 %.

Worst-case deviation

+1.656 % / −1.644 %

9.8356 kΩ to 10.166 kΩ

Lowest resistance
9.8356 kΩ at −40 °C
Highest resistance
10.166 kΩ at −40 °C
Initial tolerance
±1 %
Temperature drift alone
±0.650 % 100 ppm/°C × 65 °C
Simple sum (tol + TCR × ΔT + drift)
±1.650 % first-order estimate
Total spread
330 Ω

A datasheet TCR is a ± limit: a given part may drift up or down, so the band widens on both sides away from the reference temperature.

Deviation from 10 kΩ over temperature
-2-1.5-1-0.500.511.52-40-20020406080100Temperature (°C)Deviation (%)ref 25 °C
HighestNominal (zero TCR)Lowest

Worst-case resistance across the range

TemperatureLowestHighestDeviation
−40 °C9.8356 kΩ10.166 kΩ−1.64 % to +1.66 %
−25 °C9.8505 kΩ10.15 kΩ−1.49 % to +1.50 %
0 °C9.8752 kΩ10.125 kΩ−1.25 % to +1.25 %
25 °C9.9 kΩ10.1 kΩ−1.00 % to +1.00 %
50 °C9.8752 kΩ10.125 kΩ−1.25 % to +1.25 %
75 °C9.8505 kΩ10.15 kΩ−1.49 % to +1.50 %
85 °C9.8406 kΩ10.161 kΩ−1.59 % to +1.61 %

How do you calculate the worst-case resistance from tolerance and TCR?

Multiply the errors: Rmax = R × (1 + tol) × (1 + TCR × ΔT) and Rmin = R × (1 − tol) × (1 − TCR × ΔT), where ΔT is the largest step from the reference temperature. A 10 kΩ ±1 % resistor with ±100 ppm/°C, used from −40 °C to 85 °C with a 25 °C reference (ΔT = 65 °C), can be anywhere from 9.8356 kΩ to 10.166 kΩ, about ±1.66 %.

Resistor tolerance formula and TCR formula

The temperature coefficient of resistance formula gives the average slope of resistance against temperature, relative to the value at the reference temperature, as Vishay’s application note defines it:

α = (R(T) − R(Tref)) ÷ (R(Tref) × (T − Tref))
α
TCR in 1/°C (× 10⁶ for ppm/°C)
R(T)
resistance at temperature T
Tref
reference temperature, usually 20 °C or 25 °C

A datasheet TCR of ±X ppm/°C is a limit, not a slope: one part may rise with temperature and the next may fall. So the band widens on both sides as you move away from the reference, and each source of error multiplies:

Rmax = R(1 + tol)(1 + α ΔT)(1 + d)    Rmin = R(1 − tol)(1 − α ΔT)(1 − d)
tol
initial tolerance as a fraction (1 % = 0.01)
ΔT
largest |T − Tref| over the operating range
d
optional extra drift: load life, soldering heat

With a known signed slope (copper, or a measured part) the band moves instead: R(T) = R(1 ± tol)(1 + α(T − Tref)). Working backwards, the largest TCR that fits a ±B budget is the smaller of the two sides:

α max = min[ (1 + B) ÷ ((1 + tol)(1 + d)) − 1,  1 − (1 − B) ÷ ((1 − tol)(1 − d)) ] ÷ ΔT

Worked examples

Example 1: a 1 % thick film resistor, −40 °C to 85 °C

10 kΩ, ±1 %, ±100 ppm/°C, 25 °C reference. The cold end is further away: ΔT = 25 − (−40) = 65 °C, so the temperature term is ±0.65 %. Rmax = 10 kΩ × 1.01 × 1.0065 = 10.166 kΩ and Rmin = 10 kΩ × 0.99 × 0.9935 = 9.8356 kΩ: +1.656 % / −1.644 %.

Example 2: 0.1 % thin film over −40 °C to 125 °C, with drift

±0.1 %, ±25 ppm/°C, plus ±0.1 % allowed for soldering and load life. ΔT = 100 °C gives ±0.25 % from temperature, and the worst case is +0.451 % / −0.449 % (9.9551 kΩ to 10.045 kΩ for 10 kΩ). Over a wide range the TCR, not the 0.1 % tolerance, is the larger error.

Example 3: a copper shunt (signed TCR)

Copper’s coefficient is +3930 ppm/°C at 20 °C (the IEC value for standard copper). A 10 mΩ copper shunt at 100 °C reads R × (1 + 0.00393 × 80) = 13.14 mΩ, +31.4 %. Every copper shunt follows the same slope, so the band shifts rather than widens, and a firmware correction can take most of it out if the temperature is measured.

Example 4: what TCR does a ±0.5 % budget allow?

With ±0.1 % parts over −40 °C to 85 °C (ΔT = 65 °C), the temperature term may use about ±0.400 %, so the TCR must be at most 61.5 ppm/°C. The loosest common grade under that is ±50 ppm/°C: metal film axial (YAGEO MFR) or thin film chip (Vishay TNPW).

Drift from TCR alone

±TCR × ΔT as a percentage. Find your TCR and the largest step from the reference temperature.

TCR \ ΔT10 °C25 °C50 °C65 °C100 °C
±10 ppm/°C±0.010 %±0.025 %±0.050 %±0.065 %±0.100 %
±25 ppm/°C±0.025 %±0.063 %±0.125 %±0.162 %±0.250 %
±50 ppm/°C±0.050 %±0.125 %±0.250 %±0.325 %±0.500 %
±100 ppm/°C±0.100 %±0.250 %±0.500 %±0.650 %±1.000 %
±200 ppm/°C±0.200 %±0.500 %±1.000 %±1.300 %±2.000 %

Worst-case error for common resistor grades

Tolerance and TCR together, reference 25 °C, no extra drift. Each cell is the larger of the high and low deviations.

Grade0 to 70 °C−40 to 85 °C−40 to 125 °C−55 to 155 °C
±5 %, ±200 ppm/°C±5.95 %±6.36 %±7.10 %±7.73 %
±1 %, ±100 ppm/°C±1.45 %±1.66 %±2.01 %±2.31 %
±1 %, ±50 ppm/°C±1.23 %±1.33 %±1.51 %±1.66 %
±0.1 %, ±25 ppm/°C±0.21 %±0.26 %±0.35 %±0.43 %
±0.1 %, ±10 ppm/°C±0.15 %±0.17 %±0.20 %±0.23 %

Where the simple model stops

TCR is an average slope

Real resistance-temperature curves bend slightly. Vishay describes the TCR as the mean slope of the curve, valid only over the temperature range it was specified for, and its foil-resistor note shows that a chord TCR can misstate the change at points in between. For errors below about 0.1 %, measure or use the curve the maker publishes.

  • Self-heating counts. A resistor dissipating power runs above ambient (Vishay’s foil-resistor note calls out current-sense resistors), so use the part’s own temperature, not the room’s, for the maximum.
  • Ratios are kinder than absolutes. In a divider both resistors move together if they track, so their ratio drifts less than either value. Vishay’s foil-resistor note says the best tracking comes from resistors formed on the same substrate, as in a resistor network; two separate parts can drift in opposite directions.
  • Add stability from the datasheet as extra drift: Vishay CRCW, for example, allows up to 1 % change after 1000 h at rated power, as much as the 1 % tolerance itself.
  • Tolerance is a limit, not a distribution. A design that has to work every time should be checked with every part at its limit.

Glossary

Tolerance
How far a new resistor may be from its marked value at the reference temperature, for example ±1 %.
TCR
Temperature coefficient of resistance: the change in resistance per degree, in ppm/°C (ppm/K).
ppm
Parts per million. 100 ppm = 0.01 %.
Reference temperature
The temperature where the nominal value and tolerance apply, often 20 °C or 25 °C.
Worst case
Every error at its limit in the same direction at once, the bound a design must survive.
Drift
Change in value over time or after stress, such as load life or soldering heat, listed under stability in a datasheet.

Related guides

Frequently asked questions

What is resistor tolerance, and what does 1 % mean?

How far a new part, at the reference temperature, may be from its marking: a 10 kΩ 1 % resistor measures 9.9 kΩ to 10.1 kΩ. Temperature, soldering heat and aging move it further, which is what this calculator adds.

What does a TCR of 100 ppm/°C mean?

The resistance may change by up to 100 parts per million, 0.01 %, for each degree away from the reference temperature. Over a 65 °C step that is ±0.65 %, comparable to a 1 % tolerance.

How do I combine tolerance and temperature coefficient?

Multiply the factors: Rmax = R (1 + tol)(1 + TCR × ΔT). For 10 kΩ ±1 % with ±100 ppm/°C over −40 °C to 85 °C that gives 9.8356 kΩ to 10.166 kΩ. Simply adding the percentages (±1.650 %) is close enough for small values.

Does it also work as a resistor TCR calculator?

Yes. It takes a ± datasheet limit or a known signed slope in ppm/°C, and the “TCR for an error budget” tab works back to the largest TCR a budget allows.

What TCR do thick film, thin film and metal film resistors have?

Vishay CRCW thick film chips are ±200 ppm/K at 5 % and ±100 ppm/K at 1 % (a ±200 ppm/K grade is also listed at 1 % below 10 Ω); standard-power YAGEO RC chips from 0402 up are ±100 ppm/°C above 10 Ω and up to 10 MΩ. Vishay TNPW thin film chips come in ±50, ±25, ±15 and ±10 ppm/K, and YAGEO MFR metal film axials in ±50 and ±100 ppm/°C.

Is ppm/°C the same as ppm/K?

Yes. A temperature difference of one degree Celsius equals one kelvin, so a TCR in ppm/°C and in ppm/K is the same number.

From what temperature is TCR measured?

From the datasheet reference. YAGEO tests its RC chips from +25 °C to −55 °C and +125 °C (MIL-STD-202 Method 304), while Vishay Beyschlag’s application note uses 20 °C. Enter the reference your datasheet uses; it moves the worst-case end.

Why does a copper trace or wire make a poor precision resistor?

Copper has a TCR of about +3930 ppm/°C (the IEC value for standard copper at 20 °C, NBS Handbook 100), forty times a 1 % thick film part. A 10 mΩ copper shunt reads 31.4 % high at 100 °C.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac

Free to start. No card required.