NewAI Part GeneratorFree to get started
FREE TOOL

Strain gauge calculator

From the strain, gauge factor and excitation, this strain gauge calculator returns the output of a quarter, half or full bridge. Run it as a microstrain calculator to work back from a measured voltage. The result uses the exact bridge equation, so the nonlinearity is included, and on a quarter bridge you can enter the lead resistance to account for long lead wires.

Solve for
Examples
µε

Positive for tension, negative for compression.

From the gauge package. Metal foil is usually near 2.

V
Ω

Commonly 120, 350 or 1000 Ω.

Ω

Optional: one conductor of the gauge cable.

Lead wiring

Bridge output

2.4975 mV

Output ratio
0.4995 mV/V
Linear estimate
2.5 mV
Bridge nonlinearity η
0.0999 %
Sensitivity
1 × quarter bridge
Gauge resistance change
700 mΩ at full ε
Bridge current
14.29 mA
Power in each gauge
17.86 mW

Measures axial and bending strain together. A lone gauge has no temperature compensation; a dummy gauge in the adjacent arm (quarter-bridge type II) adds it without changing the output.

Positive strain is tension. The sign of the voltage depends on which output lead you call positive, so swap them if your reading is reversed.

Bridge output against strain
-6m-4m-2m02m4m6m-0.3-0.2-0.100.10.2-2000-1500-1000-5000500100015002000Strain (µε)Output (V)Nonlinearity (%)1000 µε
Exact outputLinear estimateNonlinearity (%)

Every arrangement at 1000 µε (GF 2, 5 V, ν 0.3)

Bridge× quarterOutputmV/VNonlinearity
Quarter bridge: 1 active gauge12.498 mV0.49950.0999 %
Half bridge: axial + Poisson gauge1.33.248 mV0.64950.07 %
Half bridge: ±ε pair (bending)25 mV10
Half bridge: 2 gauges, same strain, opposite arms24.995 mV0.9990.0999 %
Full bridge: 2 axial + 2 Poisson (column)2.66.495 mV1.2990.07 %
Full bridge: 2 axial + 2 Poisson (beam)2.66.5 mV1.30
Full bridge: 4 active ±ε (bending or torsion)410 mV20

What is the strain gauge formula for bridge output?

For a quarter bridge, Vo = Vex × GF·ε / (4 + 2·GF·ε). With a gauge factor of 2, 5 V excitation and 1000 µε, the output is 2.498 mV, against 2.5 mV from the common GF·ε / 4 shortcut. A half bridge with a ±ε pair gives 5 mV and a full bridge of four active gauges gives 10 mV.

Strain gauge formula and bridge equations

The strain gauge equation is ΔR/R = GF × ε: a gauge bonded to a part changes resistance in proportion to the strain under it. Four arms in a Wheatstone bridge turn that small change into a differential voltage.

ΔR / R = GF × ε
ΔR/R
fractional resistance change of a gauge
GF
gauge factor from the gauge package
ε
strain, as a ratio (1000 µε = 0.001)

For a strain gauge Wheatstone bridge with four equal arms, the small-signal output is the sum of the arm changes, with adjacent arms subtracting:

Vo / Vex ≈ ¼ × (ΔR₁/R − ΔR₂/R + ΔR₃/R − ΔR₄/R)

The exact output depends on the arrangement. The quarter bridge is the one you will meet most often:

Vo / Vex = GF·ε / (4 + 2·GF·ε)
Vo
bridge output, change from zero strain
Vex
excitation voltage

Nonlinearity and working back from a reading

TN-507-1 writes each output as K·ε·(1 − η), where K is the small-signal sensitivity and η the nonlinearity. For the quarter bridge η = GF·ε / (2 + GF·ε). The same equation solved for strain is the correction for a reading:

ε = 4V / (GF × (1 − 2V))
V
measured Vo / Vex

The calculator uses the closed-form solution for every arrangement. It assumes a constant-voltage supply, a high-impedance amplifier, and equal arms across each output corner.

Strain gauge calculation examples

Example 1: quarter bridge at 1000 µε

GF = 2 and ε = 1000 µε give ΔR/R = 0.002, which is 700 mΩ on a 350 Ω gauge. At 5 V: Vo = 5 × 0.002 / (4 + 2 × 0.002) = 2.498 mV. The linear estimate is 2.5 mV, so the nonlinearity is 0.0999 %, and each gauge dissipates 17.9 mW.

Example 2: full-bridge column in compression

Two axial and two Poisson gauges on a column, ν = 0.30, GF = 2, 10 V excitation, ε = −500 µε. Then Vo = 10 × (−0.001 × 1.3) / (2 + (−0.001 × 0.7)) = -6.502 mV. The linear estimate is -6.5 mV. Nonlinearity is -0.035 %: negative because in compression the output magnitude runs above the linear line.

Example 3: strain from a 12 mV reading on long leads

A 120 Ω quarter bridge at 5 V, GF = 2, wired with three conductors of 0.85 Ω each, reads 12 mV after zeroing, so V = 2.4 mV/V. The linear formula says 4800 µε. Correcting for the bridge alone gives 4823.2 µε, and including the leads gives 4857.3 µε. As a check, that strain produces 12 mV.

Strain gauge bridge configurations compared

Output at 1000 µε with GF = 2 and ν = 0.30. The case numbers are those of TN-507-1, Table 1, and the names in the second column are NI’s. Nonlinearity of zero means the arm currents stay constant.

CaseArrangementNI nameVo / VexmV/VOutput at 5 VNonlinearity
1Quarter bridge: 1 active gaugeQuarter-bridge I and IIGF·ε / (4 + 2·GF·ε)0.49952.498 mV0.0999 %
2Half bridge: axial + Poisson gaugeHalf-bridge IGF·ε(1 + ν) / (4 + 2·GF·ε(1 − ν))0.64953.248 mV0.07 %
3Half bridge: ±ε pair (bending)Half-bridge IIGF·ε / 215 mV0
4Half bridge: 2 gauges, same strain, opposite armsnoneGF·ε / (2 + GF·ε)0.9994.995 mV0.0999 %
5Full bridge: 2 axial + 2 Poisson (column)Full-bridge IIIGF·ε(1 + ν) / (2 + GF·ε(1 − ν))1.2996.495 mV0.07 %
6Full bridge: 2 axial + 2 Poisson (beam)Full-bridge IIGF·ε(1 + ν) / 21.36.5 mV0
7Full bridge: 4 active ±ε (bending or torsion)Full-bridge IGF·ε210 mV0

Quarter-bridge error against strain

GF = 2. The error in percent is roughly equal to the strain in percent, as TN-507-1 notes. In compression the output runs high instead of low.

StrainLinearExact, tensionError, tensionExact, compressionError, compression
100 µε0.05 mV/V0.049995 mV/V0.01 %-0.050005 mV/V-0.01 %
500 µε0.25 mV/V0.24988 mV/V0.05 %-0.25013 mV/V-0.05 %
1,000 µε0.5 mV/V0.4995 mV/V0.0999 %-0.5005 mV/V-0.1 %
2,000 µε1 mV/V0.998 mV/V0.2 %-1.002 mV/V-0.2 %
5,000 µε2.5 mV/V2.4876 mV/V0.498 %-2.5126 mV/V-0.503 %
10,000 µε5 mV/V4.9505 mV/V0.99 %-5.0505 mV/V-1.01 %
20,000 µε10 mV/V9.8039 mV/V1.96 %-10.204 mV/V-2.04 %
50,000 µε25 mV/V23.81 mV/V4.76 %-26.316 mV/V-5.26 %
100,000 µε50 mV/V45.455 mV/V9.09 %-55.556 mV/V-11.1 %

What goes wrong in practice

  • Temperature: a single gauge has no compensation, so a change in temperature reads as strain. A dummy gauge in the adjacent arm, a half bridge with its gauges in adjacent arms, or a full bridge cancels it. Gauges self-temperature-compensated for the specimen material help too.
  • Self-heating: TN-502 limits excitation by power density in the grid, not by a fixed voltage. Its Case 2, 4.5 V on a 120 Ω gauge with a 0.0156 in² grid, is 2.7 W/in², too high for its stainless-steel example, where it wants 1 to 2 W/in².
  • Lead wires: two-wire hookups are only reasonable for short leads. TT-612’s example of 6 m of AWG 26 on a 120 Ω gauge gives an offset near 7000 µε, so use three wires for static quarter-bridge work.
  • Gauge resistance: 120, 350 and 1000 Ω are the common values. Higher resistance lowers the heat from the excitation and the effect of lead changes.
  • Bending in an axial test: a single gauge reads the bending as well as the axial strain. Use gauges on opposite faces (the same-strain half bridge or the full-bridge column) to cancel it.
  • Large strains: TN-507-1 notes the nonlinearity can usually be ignored for elastic strains in metals, but it reaches about 1 % at 10,000 µε and 10 % at 100,000 µε, so correct for it at large strains. Count any initial unbalance as part of the strain when you do.
  • Limits of this model: equal arms, a stiff voltage source, and ΔR/R proportional to strain. It does not include transverse sensitivity, gauge misalignment, or the gauge factor’s change with temperature.

Glossary

Strain (ε)
Change in length divided by original length. Usually quoted in microstrain (µε), parts per million.
Gauge factor (GF)
Fractional resistance change per unit strain: (ΔR/R) / ε.
Strain gage
Another spelling of strain gauge, used by Micro-Measurements and NI.
Excitation (Vex)
The voltage applied across the bridge. The output is a fraction of it, so results are quoted in mV/V.
Poisson’s ratio (ν)
Minus the ratio of transverse to axial strain. A transverse gauge sees −νε.
Bridge nonlinearity (η)
The fraction by which the output falls short of the linear K·ε estimate because the arm currents change.
Bridge completion
Fixed resistors that make up the arms of the bridge not occupied by gauges.
Leadwire desensitization
Loss of output because lead resistance in series with a gauge dilutes its ΔR/R.

Related guides

Frequently asked questions

What is the quarter-bridge strain gauge formula?

Vo / Vex = GF·ε / (4 + 2·GF·ε), which is close to GF·ε / 4 at ordinary strains. With GF = 2, 5 V excitation and 1000 µε, the exact output is 2.498 mV and the linear estimate is 2.5 mV.

How much voltage does a strain gauge bridge produce?

Very little. At 1000 µε with GF = 2 and 5 V excitation, a quarter bridge gives 2.5 mV, a half bridge with a ±ε pair gives 5 mV, and a full bridge of four active gauges gives 10 mV, so an instrumentation amplifier or a high-gain ADC is normally needed.

What is the strain gauge factor formula?

The ratio of fractional resistance change to strain: GF = (ΔR/R) / ε. Metal foil gauges are usually close to 2. Use the value printed on the gauge package, because it is measured for that lot and scales every result directly.

Why is a quarter bridge nonlinear?

When only one arm changes, the current through that side of the bridge changes as well, so the output is not quite proportional to ΔR. The error is 0.0999 % at 1000 µε and 0.99 % at 10,000 µε for GF = 2. Bridges where the resistance changes in each divider cancel, such as a ±ε pair, keep the arm currents constant and are exactly linear.

When should I use a half bridge or a full bridge instead of a quarter bridge?

A quarter bridge is the simplest, but one gauge alone has no temperature compensation and reads axial and bending strain together. A half bridge with its gauges in adjacent arms, or a full bridge, compensates temperature and multiplies the output. Pick the arrangement by what you want to reject: a ±ε pair or a four-gauge beam bridge reads bending only, and the full-bridge column reads axial strain only.

What is the difference between 2-wire and 3-wire gauge wiring?

With two wires, both leads are in the gauge arm. About 1.7 Ω of lead on a 120 Ω gauge unbalances the bridge by the equivalent of 7000 µε and costs 1.4 % of the sensitivity, and the offset drifts with cable temperature. With three wires, one lead sits in each adjacent arm, so the bridge stays balanced and the sensitivity loss is 0.7 %.

How do I convert millivolts to microstrain?

Divide the output change by the excitation to get Vo / Vex, then solve the bridge equation. For a quarter bridge, ε = 4(Vo/Vex) / (GF·(1 − 2·Vo/Vex)). Reading 12 mV on 5 V with GF = 2 gives 4823.2 µε, compared with 4800 µε from the linear formula.

What excitation voltage should I use?

The output scales directly with excitation, but so does the heat in each gauge: each arm of a balanced bridge sees half the excitation, so a 350 Ω gauge dissipates 17.9 mW at 5 V and 71.4 mW at 10 V. TN-502 sets the limit by power density, the power divided by the grid area: for moderate-accuracy static work, 2 to 5 W/in² on thick steel but only 0.2 to 0.5 W/in² on fiberglass or epoxy. A higher-resistance or larger gauge lets you use more voltage.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac

Free to start. No card required.