Pt100 chart and RTD calculator

Convert temperature to resistance and back for Pt100, Pt1000 and other platinum RTDs with the IEC 60751 Callendar-Van Dusen equation, or read common values off the Pt100 chart below. The calculator also shows the sensitivity at any point and the tolerance for classes AA, A, B and C.

Convert
Examples
Element
°C
Tolerance class
Construction

Sets the range each class is valid over.

Resistance at 100.00 °C

138.5055 Ω

Sensitivity dR/dt
0.3793 Ω/°C
Class B tolerance
±0.800 °C
Class B tolerance in resistance
±0.303 Ω
1 Ω of lead resistance reads as
2.64 °C two-wire connection

Standard IEC 60751 curve (α = 0.00385). Tolerance covers the sensor only: add lead resistance, self-heating and measurement-circuit errors.

Resistance and sensitivity against temperature
010020030040000.10.20.30.40.5-20002004006008001000Temperature (°C)Resistance (Ω)Sensitivity (Ω/°C)100.0 °C
Resistance (Ω)Sensitivity (Ω/°C)

Tolerance at 100.0 °C for a thin-film element

Class± °C± ΩValid rangeIn range
AA0.2700.1020 to 150 °CYes
A0.3500.133-30 to 300 °CYes
B0.8000.303-50 to 500 °CYes
C1.6000.607-50 to 600 °CYes

How do you calculate Pt100 resistance from temperature?

Above 0 °C, use R = R0 (1 + At + Bt²) with A = 3.9083 × 10⁻³ and B = −5.775 × 10⁻⁷. A Pt100 (R0 = 100 Ω) at 100 °C is 138.51 Ω, and it changes by 0.379 Ω per °C at that point. Below 0 °C the equation adds the term Ct³(t − 100), and a Pt1000 is exactly ten times the Pt100 value.

RTD formula: the Pt100 and Pt1000 Callendar-Van Dusen equation

IEC 60751 defines the resistance of an industrial platinum RTD with the Callendar-Van Dusen equation. The two ranges share A and B, and the C term only applies below 0 °C.

R = R0 (1 + At + Bt²)     0 to 850 °C
R
resistance at temperature t, in Ω
R0
resistance at 0 °C (100 Ω for a Pt100, 1000 Ω for a Pt1000)
t
temperature in °C
A
3.9083 × 10⁻³ °C⁻¹
B
−5.775 × 10⁻⁷ °C⁻²
C
−4.183 × 10⁻¹² °C⁻⁴ (below 0 °C only)
R = R0 (1 + At + Bt² + Ct³(t − 100))     −200 to 0 °C

Above 0 °C the inverse has a closed form. With x = R ÷ R0, the root is written so that it stays accurate close to 0 °C:

t = 2(x − 1) ÷ (A + √(A² + 4B(x − 1)))

Below 0 °C there is no simple rearrangement, so the calculator solves the quartic numerically. The sensitivity is the derivative of the same equation:

dR/dt = R0 (A + 2Bt)     above 0 °C, with C(4t³ − 300t²) added inside the bracket below 0 °C

RTD calculator examples: Pt100 and Pt1000

Example 1: a Pt100 at 100 °C

At = 0.39083 and Bt² = −0.005775, so R = 100 × (1 + 0.39083 − 0.005775) = 138.5055 Ω. The sensitivity there is 0.3793 Ω/°C, lower than the 0.3908 Ω/°C at 0 °C because B is negative.

Example 2: a Pt1000 reading 842 Ω

842 Ω is below R0, so the temperature is under 0 °C and the quartic applies. Solving it gives −40.18 °C. Substituting that temperature back returns 842.000 Ω, which confirms the result.

Example 3: what 1 Ω of lead resistance does

A two-wire Pt100 reads 110 Ω through leads totaling 1 Ω. Ignoring the leads gives 25.68 °C, while the sensor itself is at 109 Ω, or 23.11 °C: an error of 2.6 °C. The same leads on a Pt1000 reading 1100 Ω give an error of 0.26 °C.

Pt100 chart: RTD table in ohms

An RTD resistance chart from the IEC 60751 equation, every 10 °C. The temperature of a cell is its row plus its column, so row −100 and column 30 is −70 °C.

°C+0+10+20+30+40+50+60+70+80+90
−20018.5222.8327.1031.3435.5439.7243.8848.0052.1156.19
−10060.2664.3068.3372.3376.3380.3184.2788.2292.1696.09
0100.00103.90107.79111.67115.54119.40123.24127.08130.90134.71
100138.51142.29146.07149.83153.58157.33161.05164.77168.48172.17
200175.86179.53183.19186.84190.47194.10197.71201.31204.90208.48
300212.05215.61219.15222.68226.21229.72233.21236.70240.18243.64
400247.09250.53253.96257.38260.78264.18267.56270.93274.29277.64
500280.98284.30287.62290.92294.21297.49300.75304.01307.25310.49
600313.71316.92320.12323.30326.48329.64332.79335.93339.06342.18
700345.28348.38351.46354.53357.59360.64363.67366.70369.71372.71
800375.70378.68381.65384.60387.55390.48————

Pt1000 table

The same curve with R0 = 1000 Ω. Every value is ten times the Pt100 value.

°C+0+10+20+30+40+50+60+70+80+90
−200185.20228.25270.96313.35355.43397.23438.76480.05521.10561.93
−100602.56643.00683.25723.35763.28803.06842.71882.22921.60960.86
01000.001039.031077.931116.731155.411193.971232.421270.751308.971347.07
1001385.051422.931460.681498.321535.841573.251610.541647.721684.781721.73
2001758.561795.281831.881868.361904.731940.981977.122013.142049.052084.84
3002120.512156.082191.522226.852262.062297.162332.142367.012401.762436.40
4002470.922505.332539.612573.792607.852641.792675.622709.332742.932776.41
5002809.782843.032876.162909.182942.082974.873007.543040.103072.543104.87
6003137.083169.183201.153233.023264.773296.403327.923359.323390.613421.78
7003452.843483.783514.603545.313575.903606.383636.743666.993697.123727.14
8003757.043786.833816.493846.053875.493904.81————

Tolerance classes

Tolerance formulas are from IEC 60751 as listed by Texas Instruments. The ranges are the IEC 60751:2008 thermometer values quoted by JUMO and Lapp, and for class C by WIKA. The standard is a paid document we did not read directly.

ClassTolerance (°C)± at 0 °C± at 100 °C± Ω at 0 °C (Pt100)Wire-wound rangeThin-film range
AA±(0.1 + 0.0017 |t|)0.10 °C0.27 °C0.039−50 to 250 °C0 to 150 °C
A±(0.15 + 0.002 |t|)0.15 °C0.35 °C0.059−100 to 450 °C−30 to 300 °C
B±(0.3 + 0.005 |t|)0.30 °C0.80 °C0.117−196 to 600 °C−50 to 500 °C
C±(0.6 + 0.01 |t|)0.60 °C1.60 °C0.234−196 to 600 °C−50 to 600 °C

IEC 60751 was revised again in 2022, and we did not read that edition either. Senmatic's summary of it lists the same four classes, ranges and formulas as this table, but JMS lists tighter class A and B formulas for finished probes under the same edition. Check the 2022 text if your specification names it.

What goes wrong in real circuits

Lead resistance

A two-wire connection measures the leads along with the sensor. Copper leads of a few ohms round trip are enough to move a Pt100 reading by several degrees. Three-wire connections cancel the leads if the wires match, and four-wire connections remove them from the measurement. Pt1000 sensors reduce the problem tenfold.

Self-heating

The excitation current heats the element: ΔT = I²R ÷ E, where E is the self-heating coefficient. Texas Instruments gives a typical range of 2.5 mW/°C for small thin-film elements to 65 mW/°C for larger wire-wound ones. At 1 mA, a Pt100 at 0 °C dissipates 0.10 mW, which raises it by 0.040 °C to 0.0015 °C across that range. TI recommends keeping excitation below about 1 mA. The coefficient depends on the medium, so use the figure from the sensor data sheet.

Limits of this model

  • The equation describes the standard curve. A real sensor differs from it by up to its tolerance class.
  • The coefficients are for α = 0.00385 platinum. Sensors with another curve, such as α = 0.00392, need their own coefficients.
  • Tolerance classes apply only inside their stated range. Outside it, use the figure from the sensor data sheet.
  • Calibrated sensors can be fitted with their own A, B and C, which is more accurate than the standard values.

Glossary

RTD
Resistance temperature detector: a sensor whose resistance rises predictably with temperature, usually platinum.
R0
The resistance at 0 °C: 100 Ω for a Pt100 and 1000 Ω for a Pt1000.
Callendar-Van Dusen equation
The polynomial that relates platinum RTD resistance to temperature in IEC 60751.
α (alpha)
The mean resistance change per ohm per °C between 0 and 100 °C; 0.00385 for the IEC 60751 curve.
Tolerance class
The allowed deviation from the standard curve: AA, A, B or C, tightest first.
Self-heating
The temperature rise caused by the excitation current dissipating power in the sensor.

Related guides

Frequently asked questions

How do I read a Pt100 chart?

Each row is a starting temperature and each column adds to it, so row −100 and column +30 is −70 °C, where a Pt100 reads 72.33 Ω. For a temperature between the 10 °C steps, enter it in the calculator above.

What is the resistance of a Pt100 at 25 °C?

109.73 Ω. At 0 °C it is exactly 100 Ω, and near room temperature it changes by about 0.388 Ω per °C.

What is the Pt100 formula?

The Callendar-Van Dusen equation: R = R0 (1 + At + Bt²) from 0 to 850 °C, and R = R0 (1 + At + Bt² + Ct³(t − 100)) from −200 to 0 °C, with A = 3.9083 × 10⁻³, B = −5.775 × 10⁻⁷ and C = −4.183 × 10⁻¹².

How do I convert Pt100 resistance to temperature?

Above 0 °C, solve the quadratic: t = 2(x − 1) ÷ (A + √(A² + 4B(x − 1))), where x = R ÷ R0. Below 0 °C the equation is a quartic with no simple rearrangement, so firmware usually uses a lookup table and this Pt100 calculator solves it numerically. For example, 110 Ω is 25.68 °C.

What is the difference between a Pt100 and a Pt1000?

R0: 100 Ω against 1000 Ω at 0 °C. A Pt1000 has exactly ten times the resistance and ten times the sensitivity (3.91 Ω/°C at 0 °C against 0.391 Ω/°C), so the same lead resistance causes a tenth of the temperature error.

What do RTD classes AA, A, B and C mean?

They set how far a sensor may deviate from the standard curve. Class B allows ±(0.3 + 0.005 |t|) °C, which is ±0.80 °C at 100 °C, and class A allows ±0.35 °C there. Each class only applies over a stated temperature range, which depends on whether the element is wire-wound or thin-film.

How much error does lead resistance cause on a Pt100?

In a two-wire connection the leads add directly to the sensor, and each ohm reads as about 2.56 °C at 0 °C. A three-wire or four-wire connection removes most or all of it, and a Pt1000 reduces it by a factor of ten.

What does α = 0.00385 mean on an RTD?

It is the average resistance change per ohm per °C between 0 and 100 °C: (R100 − R0) ÷ (100 × R0). The IEC 60751 coefficients give 0.00385055, which is rounded to 0.00385. Sensors built to a different curve have a different α and need their own coefficients.

What temperature range does a Pt100 cover?

The IEC 60751 equation runs from −200 to 850 °C, where a Pt100 measures 18.52 Ω to 390.48 Ω. A specific sensor usually covers less: tolerance classes have narrower ranges, especially for thin-film elements.