NewAI Part GeneratorFree to get started
FREE TOOL

Coaxial cable impedance calculator

Characteristic impedance, velocity factor, capacitance, inductance and TE11 cutoff all follow from the conductor diameters and the dielectric, and this coaxial cable impedance calculator works out all five. Or find the diameter ratio for a target impedance, or check a finished cable from its datasheet capacitance and velocity.

Solve for
Examples
Diameters in

The dielectric diameter on a cable datasheet.

Hz

Optional: wavelength in the line and margin to TE11.

Characteristic impedance

49.71 Ω

Diameter ratio D / d
3.512
Velocity factor
66.0%
Capacitance
101.7 pF/m
Inductance
251.2 nH/m
Delay
5.054 ns/m
TE11 cutoff (approx.)
33.24 GHz

Stranded center conductors and braided shields are not smooth cylinders, so nominal cable dimensions read a few ohms low here. For a finished cable, use the C and VF tab with its datasheet values.

Impedance versus diameter ratio
0501001502001251020D / dZ0 (Ω)D/d 3.51
εr = 2.3Air

How to calculate coaxial cable impedance

Use Z0 = (59.96 ÷ √εr) × ln(D ÷ d), where D is the inside diameter of the shield and d is the center conductor diameter. An air line with D ÷ d = 2.3 has Z0 = 49.94 Ω. A dielectric multiplies the impedance at the same ratio by 1 ÷ √εr, so PTFE at 70 % velocity needs D ÷ d = 3.29 for 50 Ω.

Coaxial cable impedance formula and related equations

The coax impedance formula holds for concentric smooth conductors with a uniform dielectric and the TEM mode. The impedance depends only on the ratio of diameters and the dielectric, not on the size of the cable.

Z0 = (η0 ÷ (2π√εr)) × ln(D ÷ d) ≈ (59.96 ÷ √εr) × ln(D ÷ d)
D
inside diameter of the shield (dielectric diameter)
d
outside diameter of the center conductor
εr
relative permittivity of the dielectric
η0
wave impedance of free space, 376.73 Ω

Capacitance and inductance per meter follow from that Z0 and the wave speed v = c ÷ √εr, because C′ = 1 ÷ (Z0 × v) and L′ = Z0 ÷ v on any TEM line. With the velocity factor and the delay:

C′ = 2π ε0 εr ÷ ln(D ÷ d)    L′ = (µ0 ÷ 2π) × ln(D ÷ d)
VF = 1 ÷ √εr    delay = √εr ÷ c    Z0 = √(L′ ÷ C′) = 1 ÷ (C′ × VF × c)

The last relation needs no dimensions at all, so it works directly from a datasheet. The first higher mode, TE11, starts near the frequency where the mean circumference of the dielectric equals one wavelength in it:

fc(TE11) ≈ 2c ÷ (π × √εr × (D + d))

This is an approximation of a Bessel-function equation. Solving that equation numerically shows it reads within 3 % of the exact value for D/d from 1.2 to 10, on the low side for common ratios.

Worked examples

Example 1: RG-58 from its nominal dimensions

Belden 8259 lists a 0.117 in dielectric, a 0.035 in stranded conductor and 66 % velocity, so εr = 2.3. That gives Z0 = (59.96 ÷ 1.515) × ln(3.343) = 47.76 Ω, with C = 105.8 pF/m, L = 241.4 nH/m and a TE11 cutoff near 32.6 GHz. The published 101 pF/m and 66 % give 50.04 Ω, the nominal 50 Ω.

Example 2: a 50 Ω PTFE line with a 3 mm dielectric

With 70 % velocity, εr = 2.04 and D/d = exp(50 × √2.04 ÷ 59.96) = 3.291. A 3 mm dielectric needs a center conductor of 0.911 mm. The delay is 4.77 ns/m, and the TE11 cutoff is near 34.2 GHz.

Example 3: RG-316 from its datasheet C and velocity

Belden 83284 publishes 95 pF/m and 70 % velocity. Z0 = 1 ÷ (95 pF/m × 0.7 × c) = 50.16 Ω, and L′ = Z0² × C′ = 239 nH/m. The nominal impedance is 50 Ω.

Impedance versus D/d ratio

Z0 from the diameter ratio for common dielectrics, with effective εr taken from published velocity factors.

D / dAirFoam PE, VF 82%PTFE, VF 70%Solid PE, VF 66%
1.524.31 Ω19.94 Ω17.02 Ω16.05 Ω
241.56 Ω34.08 Ω29.09 Ω27.43 Ω
2.349.94 Ω40.95 Ω34.96 Ω32.96 Ω
2.554.94 Ω45.05 Ω38.46 Ω36.26 Ω
365.87 Ω54.01 Ω46.11 Ω43.47 Ω
3.371.59 Ω58.7 Ω50.11 Ω47.25 Ω
3.676.8 Ω62.98 Ω53.76 Ω50.69 Ω
483.12 Ω68.16 Ω58.18 Ω54.86 Ω
596.5 Ω79.13 Ω67.55 Ω63.69 Ω
6.5112.2 Ω92.03 Ω78.56 Ω74.07 Ω
8124.7 Ω102.2 Ω87.28 Ω82.29 Ω
10138.1 Ω113.2 Ω96.64 Ω91.12 Ω

Common cables: the formula against the datasheet

Nominal dimensions and datasheet values from Belden. The From dimensions column shows how far the smooth-cylinder formula is from nominal on real cable, while the From C and VF column stays within about 2 %.

CableConductordDVFFrom dimensionsFrom C and VFNominalTE11 (approx.)
RG-58 (Belden 8259)19-strand0.035 in0.117 in66%47.76 Ω50.04 Ω50 Ω32.6 GHz
RG-174 (Belden 8216)7-strand0.019 in0.06 in66%45.5 Ω50.04 Ω50 Ω62.8 GHz
RG-316 (Belden 83284)7-strand0.02 in0.06 in70%46.11 Ω50.16 Ω50 Ω65.7 GHz
RG-6 (Belden 1694A)solid0.04 in0.18 in82%73.95 Ω76.61 Ω75 Ω28 GHz

Optimum aspect ratios for air-spaced line

For a fixed shield size, each goal has one best ratio x = D ÷ d. Lowest conductor loss minimizes (1 + x) ÷ ln x, highest peak power maximizes ln x ÷ x², and highest breakdown voltage maximizes ln x ÷ x. Microwaves101 gives the same 30 Ω and 77 Ω figures and calls 50 Ω a compromise between them.

GoalD / dZ0 in air
Highest peak power (air)1.64929.98 Ω
Highest breakdown voltage (air)2.71859.96 Ω
Lowest conductor loss (air)3.59176.65 Ω

Where the formula stops being enough

Any coaxial line impedance calculator that works from diameters, this one included, assumes smooth, concentric conductors. Stranding makes the center conductor effectively thinner than its overall diameter, and a braid has an effective diameter larger than the dielectric beneath it, so the formula reads low on braided cable. Off-center conductors, connector transitions and manufacturing tolerance also move real impedance. Foamed dielectrics have a velocity that varies with foam density, so use the figure for your exact cable. Keep the highest signal frequency well below TE11: the formula here is approximate, and makers generally stop at about 90 % of the cutoff.

Glossary

Characteristic impedance (Z0)
The ratio of voltage to current in a wave traveling along the line, set by its geometry and dielectric.
Velocity factor (VF)
The signal speed in the line as a fraction of the speed of light, 1 ÷ √εr.
Relative permittivity (εr)
How much a dielectric increases capacitance compared with a vacuum.
TEM mode
The normal coax mode, with electric and magnetic fields both transverse to the line. It has no cutoff frequency.
TE11 mode
The first higher-order mode in coax. It sets the upper frequency limit for single-mode operation.
Dielectric diameter
The outside diameter of the insulation on a cable datasheet, which equals the inside diameter of the shield.

Related guides

Frequently asked questions

What is the coaxial cable characteristic impedance formula?

Z0 = (59.96 ÷ √εr) × ln(D ÷ d), where D is the inside diameter of the shield, d is the outside diameter of the center conductor and εr is the relative permittivity of the dielectric.

Why does the coax impedance calculator give about 47.8 Ω for RG-58 instead of 50 Ω?

Because nominal dimensions describe smooth cylinders, and a real cable has a stranded center conductor and a braided shield. Both shift the effective diameters so the simple formula reads a few ohms low. The cable’s published capacitance and velocity give 50.04 Ω through Z0 = 1 ÷ (C × v): use the coax calculator’s From C and VF tab for finished cable.

What D/d ratio gives 50 Ω?

2.302 in air, 3.291 with PTFE at 70 % velocity, and 3.538 with solid PE at 66 % velocity. A higher relative permittivity needs a larger ratio for the same impedance.

How do I find velocity factor from the dielectric?

VF = 1 ÷ √εr. Solid polyethylene cable is about 66 % and solid PTFE about 70 %. Foamed dielectrics are faster, 82 % for the foam PE in Belden 1694A, because the air in the foam lowers the effective permittivity.

Why is 50 Ω the standard coax impedance?

It is a compromise. Air-spaced coax has its lowest conductor loss near 77 Ω and handles the most peak power near 30 Ω. Fifty ohms sits between the two; 75 Ω is used where low loss matters more than power.

What limits the highest frequency of a coax cable?

TE11 sets the hard limit: above its cutoff a second mode can propagate with a different velocity and the single-impedance model no longer holds, so makers generally specify connectors and air lines at no more than about 90 % of it. Larger cable has a lower cutoff. In flexible cable, loss usually limits use first: Belden lists RG-58 at 22.8 dB per 100 ft at 1 GHz, with TE11 near 32.6 GHz.

Does this coaxial cable calculator include cable loss?

No. It covers impedance, velocity factor, capacitance, inductance and TE11 cutoff, so read attenuation from the cable’s datasheet. Belden lists RG-58 at 22.8 dB per 100 ft at 1 GHz.

Does this work as a coaxial cable inductance calculator?

Yes. It reports inductance and capacitance per meter, from L′ = (µ0 ÷ 2π) × ln(D ÷ d) and C′ = 2π ε0 εr ÷ ln(D ÷ d). The nominal dimensions of RG-58 give 241.4 nH/m and 105.8 pF/m.

How do I measure the capacitance of a cable to find its impedance?

Measure the capacitance of a known open-ended length and divide by the length, then use the velocity factor from the datasheet or a time-domain reflection measurement. Keep the length short compared with a quarter wavelength at the meter’s test frequency.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac

Free to start. No card required.