What is the coaxial cable characteristic impedance formula?
Z0 = (59.96 ÷ √εr) × ln(D ÷ d), where D is the inside diameter of the shield, d is the outside diameter of the center conductor and εr is the relative permittivity of the dielectric.
Characteristic impedance, velocity factor, capacitance, inductance and TE11 cutoff all follow from the conductor diameters and the dielectric, and this coaxial cable impedance calculator works out all five. Or find the diameter ratio for a target impedance, or check a finished cable from its datasheet capacitance and velocity.
The dielectric diameter on a cable datasheet.
Optional: wavelength in the line and margin to TE11.
Characteristic impedance
49.71 Ω
Stranded center conductors and braided shields are not smooth cylinders, so nominal cable dimensions read a few ohms low here. For a finished cable, use the C and VF tab with its datasheet values.
Use Z0 = (59.96 ÷ √εr) × ln(D ÷ d), where D is the inside diameter of the shield and d is the center conductor diameter. An air line with D ÷ d = 2.3 has Z0 = 49.94 Ω. A dielectric multiplies the impedance at the same ratio by 1 ÷ √εr, so PTFE at 70 % velocity needs D ÷ d = 3.29 for 50 Ω.
The coax impedance formula holds for concentric smooth conductors with a uniform dielectric and the TEM mode. The impedance depends only on the ratio of diameters and the dielectric, not on the size of the cable.
Capacitance and inductance per meter follow from that Z0 and the wave speed v = c ÷ √εr, because C′ = 1 ÷ (Z0 × v) and L′ = Z0 ÷ v on any TEM line. With the velocity factor and the delay:
The last relation needs no dimensions at all, so it works directly from a datasheet. The first higher mode, TE11, starts near the frequency where the mean circumference of the dielectric equals one wavelength in it:
This is an approximation of a Bessel-function equation. Solving that equation numerically shows it reads within 3 % of the exact value for D/d from 1.2 to 10, on the low side for common ratios.
Belden 8259 lists a 0.117 in dielectric, a 0.035 in stranded conductor and 66 % velocity, so εr = 2.3. That gives Z0 = (59.96 ÷ 1.515) × ln(3.343) = 47.76 Ω, with C = 105.8 pF/m, L = 241.4 nH/m and a TE11 cutoff near 32.6 GHz. The published 101 pF/m and 66 % give 50.04 Ω, the nominal 50 Ω.
With 70 % velocity, εr = 2.04 and D/d = exp(50 × √2.04 ÷ 59.96) = 3.291. A 3 mm dielectric needs a center conductor of 0.911 mm. The delay is 4.77 ns/m, and the TE11 cutoff is near 34.2 GHz.
Belden 83284 publishes 95 pF/m and 70 % velocity. Z0 = 1 ÷ (95 pF/m × 0.7 × c) = 50.16 Ω, and L′ = Z0² × C′ = 239 nH/m. The nominal impedance is 50 Ω.
Z0 from the diameter ratio for common dielectrics, with effective εr taken from published velocity factors.
| D / d | Air | Foam PE, VF 82% | PTFE, VF 70% | Solid PE, VF 66% |
|---|---|---|---|---|
| 1.5 | 24.31 Ω | 19.94 Ω | 17.02 Ω | 16.05 Ω |
| 2 | 41.56 Ω | 34.08 Ω | 29.09 Ω | 27.43 Ω |
| 2.3 | 49.94 Ω | 40.95 Ω | 34.96 Ω | 32.96 Ω |
| 2.5 | 54.94 Ω | 45.05 Ω | 38.46 Ω | 36.26 Ω |
| 3 | 65.87 Ω | 54.01 Ω | 46.11 Ω | 43.47 Ω |
| 3.3 | 71.59 Ω | 58.7 Ω | 50.11 Ω | 47.25 Ω |
| 3.6 | 76.8 Ω | 62.98 Ω | 53.76 Ω | 50.69 Ω |
| 4 | 83.12 Ω | 68.16 Ω | 58.18 Ω | 54.86 Ω |
| 5 | 96.5 Ω | 79.13 Ω | 67.55 Ω | 63.69 Ω |
| 6.5 | 112.2 Ω | 92.03 Ω | 78.56 Ω | 74.07 Ω |
| 8 | 124.7 Ω | 102.2 Ω | 87.28 Ω | 82.29 Ω |
| 10 | 138.1 Ω | 113.2 Ω | 96.64 Ω | 91.12 Ω |
Nominal dimensions and datasheet values from Belden. The From dimensions column shows how far the smooth-cylinder formula is from nominal on real cable, while the From C and VF column stays within about 2 %.
| Cable | Conductor | d | D | VF | From dimensions | From C and VF | Nominal | TE11 (approx.) |
|---|---|---|---|---|---|---|---|---|
| RG-58 (Belden 8259) | 19-strand | 0.035 in | 0.117 in | 66% | 47.76 Ω | 50.04 Ω | 50 Ω | 32.6 GHz |
| RG-174 (Belden 8216) | 7-strand | 0.019 in | 0.06 in | 66% | 45.5 Ω | 50.04 Ω | 50 Ω | 62.8 GHz |
| RG-316 (Belden 83284) | 7-strand | 0.02 in | 0.06 in | 70% | 46.11 Ω | 50.16 Ω | 50 Ω | 65.7 GHz |
| RG-6 (Belden 1694A) | solid | 0.04 in | 0.18 in | 82% | 73.95 Ω | 76.61 Ω | 75 Ω | 28 GHz |
For a fixed shield size, each goal has one best ratio x = D ÷ d. Lowest conductor loss minimizes (1 + x) ÷ ln x, highest peak power maximizes ln x ÷ x², and highest breakdown voltage maximizes ln x ÷ x. Microwaves101 gives the same 30 Ω and 77 Ω figures and calls 50 Ω a compromise between them.
| Goal | D / d | Z0 in air |
|---|---|---|
| Highest peak power (air) | 1.649 | 29.98 Ω |
| Highest breakdown voltage (air) | 2.718 | 59.96 Ω |
| Lowest conductor loss (air) | 3.591 | 76.65 Ω |
Any coaxial line impedance calculator that works from diameters, this one included, assumes smooth, concentric conductors. Stranding makes the center conductor effectively thinner than its overall diameter, and a braid has an effective diameter larger than the dielectric beneath it, so the formula reads low on braided cable. Off-center conductors, connector transitions and manufacturing tolerance also move real impedance. Foamed dielectrics have a velocity that varies with foam density, so use the figure for your exact cable. Keep the highest signal frequency well below TE11: the formula here is approximate, and makers generally stop at about 90 % of the cutoff.
Z0 = (59.96 ÷ √εr) × ln(D ÷ d), where D is the inside diameter of the shield, d is the outside diameter of the center conductor and εr is the relative permittivity of the dielectric.
Because nominal dimensions describe smooth cylinders, and a real cable has a stranded center conductor and a braided shield. Both shift the effective diameters so the simple formula reads a few ohms low. The cable’s published capacitance and velocity give 50.04 Ω through Z0 = 1 ÷ (C × v): use the coax calculator’s From C and VF tab for finished cable.
2.302 in air, 3.291 with PTFE at 70 % velocity, and 3.538 with solid PE at 66 % velocity. A higher relative permittivity needs a larger ratio for the same impedance.
VF = 1 ÷ √εr. Solid polyethylene cable is about 66 % and solid PTFE about 70 %. Foamed dielectrics are faster, 82 % for the foam PE in Belden 1694A, because the air in the foam lowers the effective permittivity.
It is a compromise. Air-spaced coax has its lowest conductor loss near 77 Ω and handles the most peak power near 30 Ω. Fifty ohms sits between the two; 75 Ω is used where low loss matters more than power.
TE11 sets the hard limit: above its cutoff a second mode can propagate with a different velocity and the single-impedance model no longer holds, so makers generally specify connectors and air lines at no more than about 90 % of it. Larger cable has a lower cutoff. In flexible cable, loss usually limits use first: Belden lists RG-58 at 22.8 dB per 100 ft at 1 GHz, with TE11 near 32.6 GHz.
No. It covers impedance, velocity factor, capacitance, inductance and TE11 cutoff, so read attenuation from the cable’s datasheet. Belden lists RG-58 at 22.8 dB per 100 ft at 1 GHz.
Yes. It reports inductance and capacitance per meter, from L′ = (µ0 ÷ 2π) × ln(D ÷ d) and C′ = 2π ε0 εr ÷ ln(D ÷ d). The nominal dimensions of RG-58 give 241.4 nH/m and 105.8 pF/m.
Measure the capacitance of a known open-ended length and divide by the length, then use the velocity factor from the datasheet or a time-domain reflection measurement. Keep the length short compared with a quarter wavelength at the meter’s test frequency.
See all free electronics tools →