NewAI Part GeneratorFree to get started
FREE TOOL

Op amp slew rate formula and calculator

The slew rate formula ties an op amp’s output swing to frequency. Find the full-power bandwidth from a slew rate, the slew rate a sine of a given frequency and amplitude needs, the largest clean sine at a frequency, or how long a step takes. The chart shows where slew limiting starts for every frequency at once.

Solve for
Examples
V/µs

From the datasheet, usually typical at ±15 V or the rated supply.

V
Amplitude is
V

Optional: e.g. 13.5 V for a TL072 on ±15 V (typical).

Full-power bandwidth

15.92 kHz

Peak amplitude
10 V
Peak-to-peak
20 V
RMS (sine)
7.071 V

This limit marks where the sine visibly turns into a triangle. Distortion starts rising before it, so leave margin when THD matters.

Largest undistorted sine against frequency
100m1101001k10k100k1MFrequency (Hz)Peak amplitude (V)10 V peak15.92 kHz

How to calculate slew rate and full-power bandwidth

FPBW = SR ÷ (2π × Vp), with SR in volts per second and Vp the peak output. An op amp with a 0.5 V/µs slew rate delivers a 10 V peak sine cleanly up to 7.96 kHz. Turned around, a sine needs SR ≥ 2π × f × Vp: a 20 kHz, 10 V peak audio signal needs at least 1.257 V/µs.

Op amp slew rate formula

The slew rate equation for a sine comes from its slope: Vp·sin(2πft) changes fastest at its zero crossings, where the slope is 2πf·Vp. When that slope is more than the op amp’s slew rate, the output falls behind and the sine bends into a triangle.

SR ≥ 2π × f × Vp     FPBW = SR ÷ (2π × Vp)     Vp,max = SR ÷ (2π × f)
SR
slew rate in V/s (datasheets quote V/µs; 1 V/µs = 10⁶ V/s)
f
signal frequency in Hz
Vp
peak output amplitude in V (half the peak-to-peak, √2 × RMS)

For a step of ΔV, slewing takes ΔV ÷ SR. Small steps are limited by the closed-loop bandwidth instead:

t(slew) = ΔV ÷ SR     tr(10–90%) = 0.35 ÷ f−3dB     slew-limited when ΔV ≥ 0.35 × SR ÷ f−3dB
f−3dB
closed-loop −3 dB bandwidth (GBW ÷ noise gain)
ΔV
output step size

The last condition is the rule from National’s Linear Brief 19. In a single-pole model the output starts to slew for any step above SR ÷ (2π f−3dB), where the linear response’s initial slope ΔV ÷ τ reaches the slew rate; the calculator models the ramp-then-exponential edge for steps in between.

Slew rate calculation examples

Example 1: a 20 kHz, 10 V peak audio output

SR = 2π × 20 kHz × 10 V = 1.257 V/µs. An LM358 (0.3 V/µs typical) can only deliver 2.39 V peak at 20 kHz, while a TL072 (20 V/µs typical) has 15.9 times the slew rate needed.

Example 2: full-power bandwidth of a µA741

With 0.5 V/µs and a 13 V peak output, FPBW = 0.5 × 10⁶ ÷ (2π × 13) = 6.12 kHz, in line with the “approximately 6 kHz” Linear Brief 19 quotes for the 741. At 10 V peak it rises to 7.96 kHz.

Example 3: a 10 V step at 20 V/µs in a 3 MHz loop

Slewing the full step takes 10 V ÷ 20 V/µs = 500 ns. The loop alone would give a 10–90% rise time of 117 ns, but any step above 2.33 V is slew-limited by the LB-19 rule (and above 1.06 V starts with a ramp), so the modeled 10–90% edge is 400 ns: the slew rate, not the bandwidth, sets it.

Slew rate needed for a sine wave

Minimum slew rate, 2π × f × Vp, in V/µs. Rows are frequency, columns the peak output amplitude.

Frequency100 mV peak1 V peak5 V peak10 V peak
1 kHz0.000628 V/µs0.00628 V/µs0.0314 V/µs0.0628 V/µs
10 kHz0.00628 V/µs0.0628 V/µs0.314 V/µs0.628 V/µs
20 kHz0.0126 V/µs0.126 V/µs0.628 V/µs1.26 V/µs
100 kHz0.0628 V/µs0.628 V/µs3.14 V/µs6.28 V/µs
1 MHz0.628 V/µs6.28 V/µs31.4 V/µs62.8 V/µs
10 MHz6.28 V/µs62.8 V/µs314 V/µs628 V/µs

Slew rate of op amps and their full-power bandwidth

Typical slew rates from each TI datasheet, at the conditions listed. The output must also be able to swing to the amplitude: an LM358 on 5 V cannot reach 10 V peak at any frequency.

Op ampSlew rate (typ)FPBW at 1 V peakFPBW at 2.5 V peakFPBW at 10 V peakDatasheet
LM358, LM358A0.3 V/µs (G = +1, VS = 5 V)47.7 kHz19.1 kHz4.77 kHzSLOS068AB
LM358B0.5 V/µs (G = +1, 5 V to 36 V)79.6 kHz31.8 kHz7.96 kHzSLOS068AB
µA741C0.5 V/µs (±15 V, RL = 2 kΩ, CL = 100 pF)79.6 kHz31.8 kHz7.96 kHzSLOS094H
TL072 (C, I grades)20 V/µs (±15 V, RL = 2 kΩ, CL = 100 pF; 8 V/µs min)3.18 MHz1.27 MHz318 kHzSLOS080W
OPA161227 V/µs (G = −1, ±2.25 V to ±18 V)4.3 MHz1.72 MHz430 kHzSBOS450C

Where the simple slew rate formula stops

The FPBW formula marks where a sine visibly turns triangular; it does not promise low distortion below that. TI’s note on FPBW and distortion shows THD rising before the classic limit, more so at higher closed-loop gain, and that op amps with slew-boost circuits can have two slew limits. Published figures vary too: the OPA1612 datasheet defines FPBW with this formula, yet lists 4 MHz at 1 Vpp where 27 V/µs gives 8.59 MHz. Design with the minimum slew rate where the datasheet gives one (8 V/µs for the TL072 against 20 V/µs typical), leave margin for distortion, and remember that capacitive loads and low supply voltages slow the output further.

Glossary

Slew rate (SR)
The fastest the output voltage can change, in V/µs, set by how fast internal currents can charge the compensation capacitance.
Full-power bandwidth (FPBW)
The highest frequency at which a sine of a given amplitude, usually the rated output swing, comes out without slew limiting.
Slew-induced distortion
The distortion when a sine is slew limited and turns triangular.
Closed-loop bandwidth
The small-signal −3 dB bandwidth of the stage, GBW ÷ noise gain for a voltage-feedback op amp.
Rise time
The time from 10% to 90% of a step: 0.35 ÷ f−3dB for a single pole, ΔV ÷ SR × 0.8 when slewing.
Settling time
The time for the output to stay within a stated error band (such as 0.01%) of its final value after a step.

Related guides

Frequently asked questions

What are the slew rate and full-power bandwidth formulas?

A sine of peak Vp at frequency f changes fastest at its zero crossings, at 2π·f·Vp. The op amp must slew at least that fast: SR ≥ 2π·f·Vp. Rearranged, the full-power bandwidth is FPBW = SR ÷ (2π·Vp). A 1 V peak, 1 MHz sine needs 6.28 V/µs.

What is slew rate?

The fastest an op amp’s output voltage can change, in V/µs. It is set by how fast internal currents can charge the compensation capacitance.

How do you calculate the slew rate of an op amp from a step response?

Rearrange t(slew) = ΔV ÷ SR to SR = ΔV ÷ t: a 10 V step that slews in 500 ns is 20 V/µs. For a sine, the minimum is SR ≥ 2π·f·Vp.

What slew rate do I need for audio?

For a full 20 kHz bandwidth at 10 V peak (a large output on ±15 V rails), 1.257 V/µs; at 1 V peak, 0.1257 V/µs. An LM358’s 0.3 V/µs typical only covers 2.39 V peak at 20 kHz.

What is the full-power bandwidth of a 741?

With its 0.5 V/µs typical slew rate, 7.96 kHz at 10 V peak and 6.12 kHz at 13 V peak. Above that a full-swing sine turns into a triangle.

What happens when an op amp is slew-rate limited?

The output can no longer follow the input: a sine turns into a triangle with a smaller amplitude and a phase lag, and slew rate distortion rises sharply. The feedback loop is effectively open while the output slews, so the circuit stops behaving like its small-signal model.

Is slew rate the same as bandwidth?

No. Bandwidth (GBW ÷ noise gain) limits small signals and does not depend on amplitude; slew rate limits large signals and does. A stage can have plenty of bandwidth for a 10 mV signal and still distort a 10 V one at the same frequency.

How long does an op amp take to respond to a step?

About ΔV ÷ SR for a large step: 10 V at 20 V/µs takes 500 ns. A small step does not slew at all; its 10–90% rise time is 0.35 ÷ f−3dB, set by the closed-loop bandwidth. In a 3 MHz loop the crossover is around 2.33 V (LB-19 rule), and steps above 1.06 V start with a short ramp.

Does slew rate change with supply voltage, load or gain?

Yes, somewhat. Datasheets specify slew rate at one supply, load and gain (for example G = +1, CL = 100 pF), and capacitive loads in particular can slow it. Rising and falling edges can also differ. Use the minimum value in this op amp slew rate calculator when the design depends on it.

More free PCB tools

See all free electronics tools →

Sources

Design the whole board, not one number

ProtoFlow is free AI PCB design software: describe a circuit and get a schematic with real parts, PCB layout with an autorouter, SPICE simulation and Gerber files. Native KiCad, Altium and EAGLE import and export. Free on macOS, Windows and Linux.

Get for Mac