Band pass filter calculator

The second RC stage loads the first, so this RC band-pass filter calculator solves the whole passive network: exact lower and upper cutoffs, center frequency, bandwidth and Q, or the capacitors that put the −3 dB points where you want them. See the frequency response, the peak gain and how far the result moves from each stage on its own.

Solve for
Examples
Stage order
Ω
F
Ω
F
Hz

Optional: gain and phase at this frequency.

Ω

Optional: output resistance of the driving stage.

Ω

Optional: input resistance of the next stage.

Passband (−3 dB)

133 Hz to 1.9 kHz

Lower cutoff fL
133.3 Hz
Upper cutoff fH
1.9 kHz
Center frequency f0
503.3 Hz √(fL·fH)
Bandwidth
1.767 kHz
Q
0.285
Peak gain
-0.906 dB ×0.901 at f0
High-pass stage alone
159.2 Hz 1/(2π·Rhp·Chp)
Low-pass stage alone
1.592 kHz 1/(2π·Rlp·Clp)

Assumes a low-impedance source and a high-impedance load. Enter either if they are within a factor of ten of the resistors.

Frequency response (Bode plot)
-50-40-30-20-100-50050101001k10kFrequency (Hz)Gain (dB)Phase (°)−3 dBfL 133 Hzf0 503 HzfH 1.9 kHz
Gain (dB)Phase (°)

How do you calculate a band pass filter cutoff frequency in a passive RC circuit?

Start from the stage corners, fL ≈ 1 ÷ (2π·R1·C1) for the high-pass and fH ≈ 1 ÷ (2π·R2·C2) for the low-pass, then correct for the overlap and loading: the exact filter is H(s) = sR1C1 ÷ (s²R1C1R2C2 + s(R1C1 + R2C2 + R1C2) + 1). For 10 kΩ, 100 nF, 100 kΩ and 1 nF the corners are 159 Hz and 1.59 kHz, but the −3 dB points are 133 Hz and 1.9 kHz, around a center of 503 Hz with a -0.91 dB peak.

Band pass filter formula and transfer function

A passive RC band-pass is an RC high-pass (series C1, R1 to ground) followed by an RC low-pass (series R2, C2 to ground), or the reverse. Each stage has its own corner, but with no buffer between them the result is one second-order band-pass.

H(s) = s·R1C1 ÷ (s²·R1C1·R2C2 + s·(R1C1 + R2C2 + R1C2) + 1)
R1, C1
the first stage (here the high-pass), in Ω and F
R2, C2
the second stage (here the low-pass), in Ω and F
R1·C2
the loading term: it disappears when R2 is much larger than R1

The other band-pass filter equations follow from that denominator:

f0 = 1 ÷ (2π√(R1C1·R2C2))
Q = √(R1C1·R2C2) ÷ (R1C1 + R2C2 + R1C2)
peak gain = R1C1 ÷ (R1C1 + R2C2 + R1C2)
fL, fH = f0 × (√(1 + 1/(4Q²)) ∓ 1/(2Q))
BW = fH − fL = f0 ÷ Q     f0 = √(fL × fH)

With the low-pass first, R1·C1 is the low-pass stage, the numerator becomes s·R2C2 (the high-pass time constant) and the loading term is still the first stage’s R times the second stage’s C. A source resistance and a load resistance keep the filter second order; the calculator includes both exactly.

Why a passive RC band-pass cannot be narrow

R1C1 + R2C2 is never less than 2√(R1C1·R2C2), so Q is at most 0.5 even before loading. At Q = 0.5 the −3 dB points are (√2 ∓ 1) × f0, a ratio of 5.83, and the peak is −6 dB. Designing for a narrower band returns an error rather than capacitor values that cannot work.

How to calculate band pass filter cutoffs and capacitors: worked examples

Example 1: 10 kΩ and 100 nF, then 100 kΩ and 1 nF

The stage corners are 159 Hz and 1.59 kHz. τ1 = 1 ms, τ2 = 100 µs and the loading term R1·C2 = 10 µs, so f0 = 1 ÷ (2π√(1 ms × 100 µs)) = 503 Hz, Q = 0.285 and the peak gain is 1 ms ÷ 1.11 ms = -0.91 dB. The −3 dB band is 133 Hz to 1.9 kHz, wider than the corners because each stage still attenuates near the other’s corner.

Example 2: capacitors for the 300 Hz to 3.4 kHz voice band

With R1 = 10 kΩ and R2 = 100 kΩ, solving the exact filter for −3 dB points at 300 Hz and 3.4 kHz gives C1 = 41.8 nF and C2 = 594 pF. The nearest E12 parts, 39 nF and 560 pF, give 321 Hz to 3.61 kHz. Sizing each stage on its own, C1 = 53.1 nF and C2 = 468 pF, would have given 256 Hz to 3.99 kHz.

Example 3: Kuphaldt’s low-pass-first filter (200 Ω, 2.5 µF, 1 µF, 1 kΩ)

Lessons In Electric Circuits simulates this filter and notes that the output never rises above 0.59 V for a 1 V input. τlp = 200 Ω × 2.5 µF = 0.5 ms, τhp = 1 kΩ × 1 µF = 1 ms and the loading term is 200 Ω × 1 µF = 0.2 ms, so the peak gain is 1 ÷ 1.7 = 0.588 at 225 Hz, with −3 dB points at 81.4 Hz and 623 Hz. The second stage’s resistor is only five times the first’s: without the loading term the peak would be 1 ÷ 1.5 = 0.667.

Exact band versus stage-corner spacing

High-pass first with R2 = 10 × R1. The first column is the low-pass corner divided by the high-pass corner; the next two show how far the exact −3 dB points move from those corners.

Corner ratiofL ÷ high-pass cornerfH ÷ low-pass cornerPeak gainQ
3×0.6341.578-2.71 dB0.422
10×0.8381.194-0.91 dB0.285
30×0.9361.068-0.31 dB0.176
100×0.9801.021-0.10 dB0.099
1000×0.9981.002-0.01 dB0.032

Band pass filter design table: capacitor values for common bands

Exact capacitors, loading included, for the high-pass stage first with R2 = 10 × R1, and the nearest E12 values.

BandfL to fHR1 / R2C1 (high-pass)C2 (low-pass)E12 C1 / C2
Audio20 Hz to 20 kHz10 kΩ / 100 kΩ794 nF79.7 pF820 nF / 82 pF
Speech / telephone300 Hz to 3.4 kHz10 kΩ / 100 kΩ41.8 nF594 pF39 nF / 560 pF
Ultrasonic 40 kHz receiver10 kHz to 160 kHz1 kΩ / 10 kΩ13.6 nF116 pF15 nF / 120 pF
Heart-rate (PPG)500 mHz to 5 Hz100 kΩ / 1 MΩ2.4 µF42.2 nF2.2 µF / 39 nF

When a passive band-pass is not enough

A passive RC band-pass suits wide bands: anti-aliasing plus DC blocking in front of an ADC, the audio band, a sensor’s signal band. It always loses some signal at the peak, its edges fall at only 20 dB per decade, and its source and load resistances are part of the filter, so enter them or buffer them out. For a narrow band (Q above 0.5) or gain in the passband, use an active multiple-feedback band-pass; for steeper edges, cascade buffered second-order high-pass and low-pass sections. Use C0G/NP0 or film capacitors where the cutoffs matter: Class 2 ceramics drift with DC bias and temperature.

Glossary

Lower and upper cutoff (fL, fH)
The two frequencies where the output is 3 dB below its peak.
Center frequency (f0)
The frequency of maximum output, the geometric mean √(fL·fH).
Bandwidth
fH − fL, the width of the passband in hertz.
Q
f0 divided by the bandwidth. Passive RC band-pass filters stay at or below 0.5.
Loading
The second stage drawing current from the first, which moves the cutoffs and lowers the peak.
Stage corner
1/(2πRC) of one RC stage on its own, unloaded.

Related guides

Frequently asked questions

How do you calculate the cutoff frequencies of a band pass filter?

Each RC stage has its own corner, 1/(2πRC): the high-pass sets the lower edge and the low-pass the upper. The exact −3 dB points sit outside those corners because the stages overlap and the second loads the first. For 10 kΩ with 100 nF and 100 kΩ with 1 nF the corners are 159 Hz and 1.59 kHz, but the −3 dB band is 133 Hz to 1.9 kHz.

What is the center frequency formula for a band pass filter?

The geometric mean of the two cutoffs, f0 = √(fL × fH), not their average. For an RC band-pass it is also 1/(2π√(R1C1R2C2)), loading included: 503 Hz for the parts above.

How do you find the bandwidth and Q of a band pass filter?

Bandwidth is fH − fL and Q is f0 divided by the bandwidth. A passive RC band-pass has real poles, so its Q is at most 0.5 and its −3 dB points are always at least 5.83 times apart.

Why is the output of my passive band pass filter smaller than the input?

Neither stage ever passes the signal completely: at the center frequency the peak gain is τhp / (τhp + τlp + R1·C2), always below 1. Kuphaldt’s example (200 Ω, 2.5 µF, 1 µF, 1 kΩ) peaks at 0.588 V per volt (-4.6 dB). Spread the stage corners further apart, or buffer the stages, to get closer to 0 dB.

Does it matter whether the high-pass or the low-pass stage comes first?

With ideal buffers no, but in a passive filter yes: the first stage’s resistor must be much smaller than the second’s. The same four parts give a -0.9 dB peak with the high-pass (10 kΩ) first, and -20.9 dB with the low-pass (100 kΩ) first.

How narrow can a passive RC band pass filter be?

Not narrower than fH/fL = 5.83 (Q = 0.5), and that only with no loading and a −6 dB peak. With R2 = 10 × R1 the limit is 6.24. For a narrow band use an active multiple-feedback band-pass or an LC resonator.

How do I design a band pass filter for a specific band?

Pick the −3 dB points you want, make R2 at least ten times R1, and solve the exact filter for C1 and C2 instead of sizing each stage on its own. For 300 Hz to 3.4 kHz with 10 kΩ and 100 kΩ that gives 41.8 nF and 594 pF; sizing the stages separately would have given 256 Hz to 3.99 kHz.

How do I choose R1 and R2 for a passive band pass filter?

Make the second stage’s resistor at least ten times the first so it barely loads it, and keep both between about 1 kΩ and 1 MΩ: lower values load the source, higher ones pick up noise and are shifted by the next stage’s input. Then let this BPF calculator solve the capacitors exactly.